Search results
Results from the WOW.Com Content Network
Liquid oxygen has a clear cyan color and is strongly paramagnetic: it can be suspended between the poles of a powerful horseshoe magnet. [2] Liquid oxygen has a density of 1.141 kg/L (1.141 g/ml), slightly denser than liquid water, and is cryogenic with a freezing point of 54.36 K (−218.79 °C; −361.82 °F) and a boiling point of 90.19 K (−182.96 °C; −297.33 °F) at 1 bar (15 psi).
Medical use liquid oxygen airgas tanks are typically 2.4 MPa (350 psi). [citation needed] All equipment coming into contact with high pressure oxygen must be "oxygen clean" and "oxygen compatible", to reduce the risk of fire. [3] [4] "Oxygen clean" means the removal of any substance that could act as a source of ignition. "Oxygen compatible ...
Most humans can function at rest with an oxygen level of 15% at one atmosphere pressure; [1] a fuel such as methane is combustable down to 12% oxygen in nitrogen. A small room of 10 meter 3 has 2.08 meter 3 (2080 liters) or 2.99 kg of oxygen which would occupy 2.62 liters if it was liquid. [2]
One of the most efficient mixtures, oxygen and hydrogen, suffers from the extremely low temperatures required for storing liquid hydrogen (around 20 K or −253.2 °C or −423.7 °F) and very low fuel density (70 kg/m 3 or 4.4 lb/cu ft, compared to RP-1 at 820 kg/m 3 or 51 lb/cu ft), necessitating large tanks that must also be lightweight and ...
Inert gas is produced on board commercial and military aircraft in order to passivate fuel tanks. On hot days, fuel vapour in fuel tanks may otherwise form a flammable or explosive mixture which if oxidized, could have catastrophic consequences. Conventionally, Air Separation Modules (ASMs) have been used to generate inert gas. ASMs contain ...
Triangular diagrams are not commonplace. The easiest way to understand them is to briefly go through three basic steps in their construction. Consider the first triangular diagram below, which shows all possible mixtures of methane, oxygen and nitrogen. Air is a mixture of about 21 volume percent oxygen, and 79 volume percent inerts (nitrogen ...
Fuel and oxygen tanks should be fastened securely and upright to a wall, post, or portable cart. An oxygen tank is especially dangerous because the gas is stored at a pressure of 21 MPa (3,000 psi; 210 atm)) when full. If the tank falls over and damages the valve, the tank can be jettisoned by the compressed oxygen escaping the cylinder at high ...
Pumps carry the fuel and oxidizer. The combustion chamber mixes and burns the two liquids. The hot exhaust is choked at the throat, which, among other things, dictates the amount of thrust produced.