  2. Air gap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Air_gap_(plumbing)

    This "air gap" is visible above the sink as a small cylindrical fixture mounted near the faucet. In the base cabinet under the sink, the drain hose from the dishwasher feeds the "top" of the air gap, and the "bottom" of the air gap is plumbed into the sink drain below the basket, or into a garbage disposal unit. When installed and maintained ...

  3. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.

  4. Plumbing fixture - Wikipedia

    en.wikipedia.org/wiki/Plumbing_fixture

    Positive air pressure will push the cover up, acting as an early warning device. The underside of the cover (centre image) is kept moist by condensation occurring and insects that go back up the drain pipe get stuck to the walls of the cover. All plumbing fixtures have traps in their drains; these traps are either internal or external to the ...

  5. Trap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Trap_(plumbing)

    These devices avoid negative pressure in the drain pipe by venting room air into the drain pipe (behind the trap). A "Chicago Loop" is another alternative. When a trap is installed on a fixture that is not routinely used—such as a floor drain—the eventual evaporation of the water in the trap must be considered.

  6. Air lock - Wikipedia

    en.wikipedia.org/wiki/Air_lock

    'S' trap inlet to drain [further explanation needed]. The air lock phenomenon can be used in a number of useful ways. An 'S' trap (a pipe that descends from a reservoir, then curves back up, then down again) allows liquid to flow from top to bottom unhindered, and gas cannot flow through the trap unless it has enough extra pressure to overcome the liquid head of the trap.

  7. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    It is designed to handle the pressure fluctuations). In the case of the upstream check valve passing, the differential pressure (higher supply pressure compared with the lower chamber pressure) causes any flow to occur only in one direction. A buildup of pressure in the chamber in such a case would be relieved to the drain.

  8. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    Backflow occurs for one of two reasons, either back pressure or back siphonage. [1] Back pressure is the result of a higher pressure in the system than in its supply, i.e. the system pressure has been increased by some means. This may occur in unvented heating systems, where thermal expansion increases the pressure.

  9. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Small pressure pan application. A third test method to determine if ductwork is leaking to the outside is to use a pressure pan, which is a register cover with a pressure tap for a hose connection. With the house pressurized (or depressurized) to 50 Pa (-50 Pa) using a blower door, a pressure gauge is attached to the pressure pan by means of a ...