enow.com Web Search

  1. Ads

    related to: 6' lay flat hose gpm 2 5

Search results

  1. Results from the WOW.Com Content Network
  2. Mattydale lay - Wikipedia

    en.wikipedia.org/wiki/Mattydale_lay

    [3] [4] [5] There are several different types of "hose loads" in use, which is the way the hose is folded in the lay: Accordion load – The hose is loaded so that when it is flat, it is standing on end. The finished load resembles an accordion. Flat load – The flat hose is simply placed in the track so that it is stacked. Most large supply ...

  3. Miner's inch - Wikipedia

    en.wikipedia.org/wiki/Miner's_inch

    The miner’s inch measures the amount of water that would flow through a slot of a given area at a given pressure (for example, at a head of 6 inches of water, or 1.5 kPa.) In miner's inch the word inch refers to the area of the slot in square inches, while the pressure in inches of water refers to the height of water above the slot. A ...

  4. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    Q = flow, gpm (gallons per minute) C = pipe roughness coefficient; d = inside pipe diameter, in (inches) Note: Caution with U S Customary Units is advised. The equation for head loss in pipes, also referred to as slope, S, expressed in "feet per foot of length" vs. in 'psi per foot of length' as described above, with the inside pipe diameter, d ...

  5. Fracking hose - Wikipedia

    en.wikipedia.org/wiki/Fracking_hose

    Hydraulic fracturing uses between 1.2 and 3.5 million US gallons (4.5 and 13.2 Ml) of water per well, with large projects using up to 5 million US gallons (19 Ml). Additional water is used when wells are refractured; this may be done several times.

  6. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    A short piece of fire hose, usually 10 to 20 feet (6.1 m) long, of large diameter, greater than 2.5 inches (64 mm) and as large as 6 inches (150 mm), used to move water from a fire hydrant to the fire engine, when the fire apparatus is parked close to the hydrant. Solid stream A fire-fighting water stream emitted from a smooth-bore nozzle.

  7. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...

  1. Ads

    related to: 6' lay flat hose gpm 2 5