Concrete cover, in reinforced concrete, is the least distance between the surface of embedded reinforcement and the outer surface of the concrete (ACI 130). The concrete cover depth can be measured with a cover meter. The purpose of concrete cover is to protect the reinforcement from corrosion, fire, and other potential damage.
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
The structure was constructed of reinforced concrete frames with hollow clay tile ribbed flooring and hollow clay tile infill walls. That practice was strongly questioned by experts and recommendations for "pure" concrete construction were made, using reinforced concrete for the floors and walls as well as the frames. [20]
Concrete which is subjected to long-duration forces is prone to creep. The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1] Reinforced concrete is the most common form of concrete. The reinforcement is often steel rebar (mesh, spiral, bars and other forms). Structural fibers of various materials are ...
Fiber-reinforced concrete or fibre ... minimum quantities of steel reinforcement within the concrete. ... to replace traditional reinforcement in vertical walls ...
A reinforcement ratio is defined as the ratio of the gross concrete area for a section taken orthogonal to the reinforcement. Construction codes of practice define maximum and minimum amounts of reinforcement as well as the detailing of steel bars. Common construction methods for in-situ reinforced concrete walls include traditional shuttered ...
The effective reinforcement ratio was determined from the maximum arching moment of resistance in a rigidly restrained concrete slab, which Rankin [21] had derived for laterally restrained concrete slabs from McDowell, McKee and Sevin's [22] arching action deformation theory for masonry walls.
The first expanded polystyrene ICF Wall forms were developed in the late 1960s with the expiration of the original patent and the advent of modern foam plastics by BASF. [citation needed] Canadian contractor Werner Gregori filed the first patent for a foam concrete form in 1966 with a block "measuring 16 inches high by 48 inches long with a tongue-and-groove interlock, metal ties, and a waffle ...