Search results
Results from the WOW.Com Content Network
Clotting time is a general term for the time required for a sample of blood to form a clot, or, in medical terms, coagulate.The term "clotting time" is often used when referring to tests such as the prothrombin time (PT), activated partial thromboplastin time (aPTT or PTT), activated clotting time (ACT), thrombin time (TT), or Reptilase time.
The thrombin time (TT), also known as the thrombin clotting time (TCT), is a blood test that measures the time it takes for a clot to form in the plasma of a blood sample containing anticoagulant, after an excess of thrombin has been added. [1] It is used to diagnose blood coagulation disorders and to assess the effectiveness of fibrinolytic ...
Activated clotting time (ACT), also known as activated coagulation time, is a test of coagulation. [1] [2]The ACT test can be used to monitor anticoagulation effects, such as from high-dose heparin before, during, and shortly after procedures that require intense anticoagulant administration, such as cardiac bypass, interventional cardiology, thrombolysis, extra-corporeal membrane oxygenation ...
Thromboelastography (TEG) is a method of testing the efficiency of blood coagulation.It is a test mainly used in surgery and anesthesiology, although increasingly used in resuscitations in emergency departments, intensive care units, and labor and delivery suites.
The division of coagulation in two pathways is arbitrary, originating from laboratory tests in which clotting times were measured either after the clotting was initiated by glass, the intrinsic pathway; or clotting was initiated by thromboplastin (a mix of tissue factor and phospholipids), the extrinsic pathway.
Fresh normal plasma has all the blood coagulation factors with normal levels. If the problem is a simple factor deficiency, mixing the patient plasma 1:1 with plasma that contains 100% of the normal factor level results in a level ≥50% in the mixture (say the patient has an activity of 0%; the average of 100% + 0% = 50%). [3]
The reference range for prothrombin time depends on the analytical method used, but is usually around 12–13 seconds (results should always be interpreted using the reference range from the laboratory that performed the test), and the INR in absence of anticoagulation therapy is 0.8–1.2.
Quality control is an important requirement in laboratory and POC testing. An automatic internal electronic control procedure is implemented in the ROTEM whole blood analyzer. Furthermore, biological control materials at 2 different levels are available and should be used in order to document quality and validity of results.