enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    Xchanger Inc, webpage Calculator for SCFM, NM3/hr, lb/hr, kg/hr, ACFM & M3/hr gas flows. onlineflow.de, webpage Online calculator for conversion of volume, mass and molar flows (SCFM, MMSCFD, Nm3/hr, kg/s, kmol/hr and more) ACFM versus SCFM for ASME AG-1 HEPA Filters; SCFM (Standard CFM) vs. ACFM (Actual CFM) (Specifically for air flows only)

  3. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  4. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Q = Volumetric flow rate of air in cubic feet per minute (cfm) Vol = Space volume L × W × H, in cubic feet; In metric units = where: ACPH = number of air changes per hour; higher values correspond to more ventilation; Q = Volumetric flow rate of air in liters per second (L/s)

  5. Airwatt - Wikipedia

    en.wikipedia.org/wiki/Airwatt

    Where airflow in Cubic Feet per Minute [CFM] is calculated using airflow = √ 13.35 × D 2 / vacuum. Where D is the diameter of the orifices. [5] [further explanation needed] CFM is always given statistically at its maximum which is at a 2-inch (51 mm) opening. Waterlift, on the other hand, is always given at its maximum: a 0-inch opening.

  6. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    For air flow at room temperature, when the outlet pressure is less than 1/2 the absolute inlet pressure, the flow becomes quite simple (although it reaches sonic velocity internally). With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm).

  7. Clean air delivery rate - Wikipedia

    en.wikipedia.org/wiki/Clean_Air_Delivery_Rate

    The clean air delivery rate (CADR) is a figure of merit that is the cubic feet per minute (CFM) of air that has had all the particles of a given size distribution removed. For air filters that have air flowing through them, it is the fraction of particles (of a particular size distribution) that have been removed from the air, multiplied by the ...

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    CFM25 is defined as the air flow (in cubic feet per minute) needed to create a 25 Pascal pressure change in the ductwork. CFM25 is one of the most basic measurements of ductwork airtightness. A pressure of 25 Pa is equal to 0.1 inches (0.25 cm) of water column.