In engineering, the Moody chart or Moody diagram (also Stanton diagram) is a graph in non-dimensional form that relates the Darcy–Weisbach friction factor f D, Reynolds number Re, and surface roughness for fully developed flow in a circular pipe. It can be used to predict pressure drop or flow rate down such a pipe.
Pressure drop (often abbreviated as "dP" or "ΔP") [1] is defined as the difference in total pressure between two points of a fluid carrying network. A pressure drop occurs when frictional forces, caused by the resistance to flow, act on a fluid as it flows through a conduit (such as a channel, pipe , or tube ).
Fanning friction factor for tube flow. This friction factor is one-fourth of the Darcy friction factor, so attention must be paid to note which one of these is meant in the "friction factor" chart or equation consulted. Of the two, the Fanning friction factor is the more commonly used by chemical engineers and those following the British ...
The following table lists historical approximations to the Colebrook–White relation [23] for pressure-driven flow. Churchill equation [ 24 ] (1977) is the only equation that can be evaluated for very slow flow (Reynolds number < 1), but the Cheng (2008), [ 25 ] and Bellos et al. (2018) [ 8 ] equations also return an approximately correct ...
Friction loss is then the change in pressure Δp per unit length of pipe L Δ p L . {\displaystyle {\frac {\Delta p}{L}}.} When the pressure is expressed in terms of the equivalent height of a column of that fluid, as is common with water, the friction loss is expressed as S , the "head loss" per length of pipe, a dimensionless quantity also ...
Which friction factor is plotted in a Moody diagram may be determined by inspection if the publisher did not include the formula described above: Observe the value of the friction factor for laminar flow at a Reynolds number of 1000. If the value of the friction factor is 0.064, then the Darcy friction factor is plotted in the Moody diagram.
In the diagram, the Fanno line reaches maximum entropy at H = 0.833 and the flow is choked. According to the Second law of thermodynamics, entropy must always increase for Fanno flow. This means that a subsonic flow entering a duct with friction will have an increase in its Mach number until the flow is choked.
The main feature of thermodynamic diagrams is the equivalence between the area in the diagram and energy. When air changes pressure and temperature during a process and prescribes a closed curve within the diagram the area enclosed by this curve is proportional to the energy which has been gained or released by the air.