Search results
Results from the WOW.Com Content Network
This template produces three or four wikitable columns that represent wins, losses, optionally ties, and a winning percentage. Template parameters [Edit template data] Parameter Description Type Status Wins 1 The amount of wins to show. Example 56 Number required Losses 2 The amount of losses to show. Example 52 Number required Ties 3 The amount of ties to show. Number optional See also {{ GP ...
A model of Melde's experiment: an electric vibrator connected to a cable drives a pulley that suspends a mass that causes tension in the cable. Melde's experiment is a scientific experiment carried out in 1859 by the German physicist Franz Melde on the standing waves produced in a tense cable originally set oscillating by a tuning fork , later ...
In a three-point bend test, a fatigue crack is created at the tip of the notch by cyclic loading. The length of the crack is measured. The specimen is then loaded monotonically. A plot of the load versus the crack opening displacement is used to determine the load at which the crack starts growing.
In electrical engineering, dielectric loss quantifies a dielectric material's inherent dissipation of electromagnetic energy (e.g. heat). [1] It can be parameterized in terms of either the loss angle δ or the corresponding loss tangent tan( δ ) .
The Hardy Cross method is an application of continuity of flow and continuity of potential to iteratively solve for flows in a pipe network. [1] In the case of pipe flow, conservation of flow means that the flow in is equal to the flow out at each junction in the pipe.
ΔE is the fluid's mechanical energy loss, ξ is an empirical loss coefficient, which is dimensionless and has a value between zero and one, 0 ≤ ξ ≤ 1, ρ is the fluid density, v 1 and v 2 are the mean flow velocities before and after the expansion. In case of an abrupt and wide expansion, the loss coefficient is equal to one. [1]
The movement of a fluid through porous media is described by the combination of Darcy's law with the principle of conservation of mass in order to express the capillary force or fluid velocity as a function of various other parameters including the effective pore radius, liquid viscosity or permeability. [3]
An abrupt 90° bend in a microstrip will cause a significant portion of the signal on the strip to be reflected back towards its source, with only part of the signal transmitted on around the bend. One means of effecting a low-reflection bend, is to curve the path of the strip in an arc of radius at least 3 times the strip-width. [23]