Neutral wires are usually connected at a neutral bus within panelboards or switchboards, and are "bonded" to earth ground at either the electrical service entrance, or at transformers within the system. For electrical installations with split-phase (three-wire single-phase) service, the neutral point of the system is at the center-tap on the ...
United States electrical codes require that the neutral be connected to earth at the "service panel" only and at no other point within the building wiring system. Formally, the neutral is called the "grounded conductor"; as of the 2008 NEC, the terms "neutral conductor" and "neutral point" have been defined in the Code to conform to what had ...
A 2.26 kΩ, 1%-precision resistor with 5 color bands (), from top, 2-2-6-1-1; the last two brown bands indicate the multiplier (×10) and the tolerance (1%).. An electronic color code or electronic colour code (see spelling differences) is used to indicate the values or ratings of electronic components, usually for resistors, but also for capacitors, inductors, diodes and others.
A somewhat similar system called "concentric wiring" was introduced in the United States around 1905. In this system, an insulated electrical wire was wrapped with copper tape which was then soldered, forming the grounded (return) conductor of the wiring system. The bare metal sheath, at earth potential, was considered safe to touch.
The international standard IEC 60446 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors was a standard published by the International Electrotechnical Commission (IEC) that defined basic safety principles for identifying electrical conductors by colours or numerals, for example in ...
Systems incorporating color-coding include: In electricity: 25-pair color code – telecommunications wiring; Audio and video interfaces and connectors § Color codes; Optical fibers § Color codes; Electrical wiring – AC power phase, neutral, and grounding wires; Electronic color code AKA resistor or EIA color code (today – IEC 60062:2016)
Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.
This is called "system grounding" and most electrical systems are required to be grounded. The U.S. NEC and the UK's BS 7671 list systems that are required to be grounded. According to the NEC, the purpose of connecting an electrical system to the physical ground (earth) is to limit the voltage imposed by lightning events and contact with ...