enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Should I turn off water if pipes are frozen? How to keep ...

    www.aol.com/turn-off-water-pipes-frozen...

    What to do when water pipes freeze. Here are tips from The Red Cross. If you turn on a faucet and only a trickle comes out, suspect a frozen pipe. Likely places for frozen pipes include against ...

  3. Thermostatic radiator valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_radiator_valve

    The valve gradually closes as the temperature of the surrounding area increases, limiting the amount of hot water entering the radiator. This allows a maximum temperature to be set for each room. As the valve works by sensing the temperature of the air surrounding it, it is important to ensure that it is not covered by material (such as curtains).

  4. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...

  5. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    A dry valve acts as an air vent until a dribble of water passes through it and swells the cartridge. If the valve dries out again, it re-opens. A characteristic of these valves is that they function best on the hot delivery side of a radiator and may not open as vents unless the water supply is hot. [8]

  6. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    A safety valve allows water to escape from the system when pressure becomes too high, and a valve can open to replenish water from the normal water supply if the pressure drops too low. Sealed systems offer an alternative to open-vent systems, in which steam can escape from the system, and gets replaced from the building's water supply via a ...

  7. Forced-air gas - Wikipedia

    en.wikipedia.org/wiki/Forced-air_gas

    Older furnaces sometimes relied on gravity instead of a blower to circulate air. [1]Gas-fired forced-air furnaces have a burner in the furnace fueled by natural gas.A blower forces cold air through a heat exchanger and then through duct-work that distributes the hot air through the building. [2]

  8. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and climate control - for example, in the case of ...

  9. Bleed screw - Wikipedia

    en.wikipedia.org/wiki/Bleed_screw

    Bleed screw key Bleed screw key in use at a domestic radiator. On a home radiator unit, the bleed screw can be opened, usually by means of a key, to allow unwanted air to escape from the unit. Bleed screws are also found on some pump types fulfilling a similar purpose. They are most often located at the top of the radiator on the side of the ...

  1. Related searches radiator valve not switching off on furnace drain pipe frozen outside water

    thermostatic radiator valve installationturning off water in frozen pipe
    thermostatic radiator valve