A low-flow fixture is a water saving plumbing fixture designed to achieve water savings by having a lower flow rate of water or a smaller quantity per flush. Some of these low-flow fixtures are faucets , showerheads, and toilets .
English: Diagram of a water distribution system. Inlet water goes through a pumping station. The water is delivered to the top of a water tank. Water pressure created by gravity and delivered to water mains. Water mains are connected to fire hydrants and service lines which are pipes that connect a water main to a building.
The flow meter utilizes a unique combination of a tapered metering cone in series with a piston. The position of the metal piston is sensed by the LVDT circuitry and is then translated into a flow rate. [citation needed] This non linear signal can be directly displayed or linearized with an electrical output.
The high flow element is typically a turbine meter. When flow rates drop to where the high flow element cannot measure accurately, a check valve closes to divert water to a smaller element that can measure the lower flow rates accurately. The low flow element is typically a multi-jet or PD meter.
For free flow, the equation to determine the flow rate is simply Q = CH a n where: Q is flowing rate (ft 3 /s) C is the free-flow coefficient for the flume (see Table 1 below) H a is the head at the primary point of measurement (ft) (See Figure 1 above) n varies with flume size (see Table 1 below) Parshall flume discharge table for free flow ...
Flow measurement is the quantification of bulk fluid movement. Flow can be measured using devices called flowmeters in various ways. The common types of flowmeters with industrial applications are listed below: Obstruction type (differential pressure or variable area) Inferential (turbine type) Electromagnetic
A positive displacement meter is a type of flow meter that requires fluid to mechanically displace components in the meter in order for flow measurement. Positive displacement (PD) flow meters measure the volumetric flow rate of a moving fluid or gas by dividing the media into fixed, metered volumes (finite increments or volumes of the fluid).
The magnetic flow meter requires a conducting fluid, for example, water that contains ions, and an electrical insulating pipe surface, for example, a rubber-lined steel tube. If the magnetic field direction were constant, electrochemical and other effects at the electrodes would make the potential difference difficult to distinguish from the ...