enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Diffraction-limited system - Wikipedia

    en.wikipedia.org/wiki/Diffraction-limited_system

    The observation of sub-wavelength structures with microscopes is difficult because of the Abbe diffraction limit.Ernst Abbe found in 1873, [2] and expressed as a formula in 1882, [3] that light with wavelength , traveling in a medium with refractive index and converging to a spot with half-angle will have a minimum resolvable distance of

  3. Optical resolution - Wikipedia

    en.wikipedia.org/wiki/Optical_resolution

    Also common in the microscopy literature is a formula for resolution that treats the above-mentioned concerns about contrast differently. [2] The resolution predicted by this formula is proportional to the Rayleigh-based formula, differing by about 20%. For estimating theoretical resolution, it may be adequate.

  4. 1951 USAF resolution test chart - Wikipedia

    en.wikipedia.org/.../1951_USAF_resolution_test_chart

    A 1951 USAF resolution test chart is a microscopic optical resolution test device originally defined by the U.S. Air Force MIL-STD-150A standard of 1951. The design provides numerous small target shapes exhibiting a stepped assortment of precise spatial frequency specimens.

  5. Angular resolution - Wikipedia

    en.wikipedia.org/wiki/Angular_resolution

    In a dry objective or condenser, this gives a maximum NA of 0.95. In a high-resolution oil immersion lens, the maximum NA is typically 1.45, when using immersion oil with a refractive index of 1.52. Due to these limitations, the resolution limit of a light microscope using visible light is about 200 nm.

  6. Dawes' limit - Wikipedia

    en.wikipedia.org/wiki/Dawes'_limit

    diffraction pattern matching Dawes' limit. Dawes' limit is a formula to express the maximum resolving power of a microscope or telescope. [1] It is so named after its discoverer, William Rutter Dawes, [2] although it is also credited to Lord Rayleigh. The formula takes different forms depending on the units.

  7. Contrast transfer function - Wikipedia

    en.wikipedia.org/wiki/Contrast_transfer_function

    The first time the function crosses the x-axis is called the point resolution; To maximize phase signal, it is generally better to use imaging conditions that push the point resolution to higher spatial frequencies; When the function is negative, that represents positive phase contrast, leading to a bright background, with dark atomic features

  8. Scherzer's theorem - Wikipedia

    en.wikipedia.org/wiki/Scherzer's_theorem

    Scherzer's theorem is a theorem in the field of electron microscopy. It states that there is a limit of resolution for electronic lenses because of unavoidable aberrations . German physicist Otto Scherzer found in 1936 [ 1 ] that the electromagnetic lenses , which are used in electron microscopes to focus the electron beam , entail unavoidable ...

  9. RESOLFT - Wikipedia

    en.wikipedia.org/wiki/RESOLFT

    Rasterisation of the whole sample results in a pixel image with extremely high resolution. RESOLFT microscopy is an optical microscopy with very high resolution that can image details in samples that cannot be imaged with conventional or confocal microscopy. Within RESOLFT the principles of STED microscopy [1] [2] and GSD microscopy are ...