enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Structural load - Wikipedia

    en.wikipedia.org/wiki/Structural_load

    The dead load includes loads that are relatively constant over time, including the weight of the structure itself, and immovable fixtures such as walls, plasterboard or carpet. The roof is also a dead load. Dead loads are also known as permanent or static loads. Building materials are not dead loads until constructed in permanent position.

  3. Eurocode 1: Actions on structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_1:_Actions_on...

    EN 1991-1-4 gives guidance on the determination of natural wind actions for the structural design of building and civil engineering works for each of the loaded areas under consideration. This includes the whole structure or parts of the structure or elements attached to the structure, e. g. components, cladding units and their fixings, safety ...

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  5. Structural engineering theory - Wikipedia

    en.wikipedia.org/wiki/Structural_engineering_theory

    A load case is a combination of different types of loads with safety factors applied to them. A structure is checked for strength and serviceability against all the load cases it is likely to experience during its lifetime. Typical load cases for design for strength (ultimate load cases; ULS) are: 1.2 x Dead Load + 1.6 x Live Load

  6. Factor of safety - Wikipedia

    en.wikipedia.org/wiki/Factor_of_safety

    In engineering, a factor of safety (FoS) or safety factor (SF) expresses how much stronger a system is than it needs to be for an intended load.Safety factors are often calculated using detailed analysis because comprehensive testing is impractical on many projects, such as bridges and buildings, but the structure's ability to carry a load must be determined to a reasonable accuracy.

  7. Structural dynamics - Wikipedia

    en.wikipedia.org/wiki/Structural_dynamics

    However, in reality loads are never applied instantaneously – they build up over a period of time (this may be very short indeed). This time is called the rise time . As the number of degrees of freedom of a structure increases it very quickly becomes too difficult to calculate the time history manually – real structures are analysed using ...

  8. Deflection (engineering) - Wikipedia

    en.wikipedia.org/wiki/Deflection_(engineering)

    Deflection (f) in engineering. In structural engineering, deflection is the degree to which a part of a long structural element (such as beam) is deformed laterally (in the direction transverse to its longitudinal axis) under a load.

  9. Limit state design - Wikipedia

    en.wikipedia.org/wiki/Limit_state_design

    Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria. [ 1 ]