Search results
Results from the WOW.Com Content Network
Goldmann perimeter The Goldmann perimeter is a hollow white spherical bowl positioned a set distance in front of the patient. [3] An examiner presents a test light of variable size and intensity. The light may move towards the center from the perimeter (kinetic perimetry), or it may remain in one location (static perimetry).
Theoretically, average corneal rigidity (taken as 520 μm for GAT) and the capillary attraction of the tear meniscus cancel each other out when the flattened area has the 3.06 mm diameter contact surface of the Goldmann prism, which is applied to the cornea using the Goldmann tonometer with a measurable amount of force from which the IOP is ...
Goldmann's perimeter (1945 development), [4] Goldmann's tonometer, [4] Goldmann's indirect goniolens, Goldmann-Weekers Dark Adaptometer™, [5] and; fluorophotometer. He was the author of more than 200 articles in peer-reviewed journals. At the eye clinic of the University of Bern there is a Hans-Goldmann-Stiftung (Foundation) for orthoptics ...
Goldmann applanation tonometry (GAT) is considered to be the gold standard IOP test and is the most widely accepted method. [4] [5] A special disinfected prism is mounted on the tonometer head and then placed against the cornea. The examiner then uses a cobalt blue filter to view two green semicircles.
The visual field is "that portion of space in which objects are visible at the same moment during steady fixation of the gaze in one direction"; [1] in ophthalmology and neurology the emphasis is mostly on the structure inside the visual field and it is then considered “the field of functional capacity obtained and recorded by means of perimetry”.
Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.
Figure 1 - Humphrey field analyser. Humphrey field analyser (HFA) is a tool for measuring the human visual field that is commonly used by optometrists, orthoptists and ophthalmologists, particularly for detecting monocular visual field.
These techniques include flicker perimetry, which assesses temporal visual function and spatial resolution targeting the M pathway; Frequency Doubling Technology (FDT), which utilizes an optical illusion to evaluate ganglion cell damage within the M pathway; Short-Wavelength Automated Perimetry (SWAP), isolating the S cone system to detect ...