enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Visual field test - Wikipedia

    en.wikipedia.org/wiki/Visual_field_test

    Goldmann perimeter The Goldmann perimeter is a hollow white spherical bowl positioned a set distance in front of the patient. [3] An examiner presents a test light of variable size and intensity. The light may move towards the center from the perimeter (kinetic perimetry), or it may remain in one location (static perimetry).

  3. Goldmann Applanation Tonometer - Wikipedia

    en.wikipedia.org/wiki/Goldmann_Applanation_Tonometer

    Theoretically, average corneal rigidity (taken as 520 μm for GAT) and the capillary attraction of the tear meniscus cancel each other out when the flattened area has the 3.06 mm diameter contact surface of the Goldmann prism, which is applied to the cornea using the Goldmann tonometer with a measurable amount of force from which the IOP is ...

  4. Hans Goldmann - Wikipedia

    en.wikipedia.org/wiki/Hans_Goldmann

    Goldmann's perimeter (1945 development), [4] Goldmann's tonometer, [4] Goldmann's indirect goniolens, Goldmann-Weekers Dark Adaptometer™, [5] and; fluorophotometer. He was the author of more than 200 articles in peer-reviewed journals. At the eye clinic of the University of Bern there is a Hans-Goldmann-Stiftung (Foundation) for orthoptics ...

  5. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    Goldmann applanation tonometry (GAT) is considered to be the gold standard IOP test and is the most widely accepted method. [4] [5] A special disinfected prism is mounted on the tonometer head and then placed against the cornea. The examiner then uses a cobalt blue filter to view two green semicircles.

  6. Visual field - Wikipedia

    en.wikipedia.org/wiki/Visual_field

    The visual field is "that portion of space in which objects are visible at the same moment during steady fixation of the gaze in one direction"; [1] in ophthalmology and neurology the emphasis is mostly on the structure inside the visual field and it is then considered “the field of functional capacity obtained and recorded by means of perimetry”.

  7. Imbert-Fick law - Wikipedia

    en.wikipedia.org/wiki/Imbert-Fick_law

    Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.

  8. Humphrey visual field analyser - Wikipedia

    en.wikipedia.org/wiki/Humphrey_Visual_Field_Analyser

    Figure 1 - Humphrey field analyser. Humphrey field analyser (HFA) is a tool for measuring the human visual field that is commonly used by optometrists, orthoptists and ophthalmologists, particularly for detecting monocular visual field.

  9. Visual pathway lesions - Wikipedia

    en.wikipedia.org/wiki/Visual_pathway_lesions

    These techniques include flicker perimetry, which assesses temporal visual function and spatial resolution targeting the M pathway; Frequency Doubling Technology (FDT), which utilizes an optical illusion to evaluate ganglion cell damage within the M pathway; Short-Wavelength Automated Perimetry (SWAP), isolating the S cone system to detect ...