Search results
Results from the WOW.Com Content Network
Abbe number. In optics and lens design, the Abbe number, also known as the V-number or constringence of a transparent material, is an approximate measure of the material's dispersion (change of refractive index versus wavelength), with high values of V indicating low dispersion. It is named after Ernst Abbe (1840–1905), the German physicist ...
Chromatic aberration. Focal length of lens varies with the color of light. In optics, chromatic aberration ( CA ), also called chromatic distortion, color aberration, color fringing, or purple fringing, is a failure of a lens to focus all colors to the same point. [ 1][ 2] It is caused by dispersion: the refractive index of the lens elements ...
In optics, the Abbe sine condition is a condition that must be fulfilled by a lens or other optical system in order for it to produce sharp images of off-axis as well as on-axis objects. It was formulated by Ernst Abbe in the context of microscopes. [1] The Abbe sine condition says that. the sine of the object-space angle should be proportional ...
An optical instrument is said to be diffraction-limited if it has reached this limit of resolution performance. Other factors may affect an optical system's performance, such as lens imperfections or aberrations, but these are caused by errors in the manufacture or calculation of a lens, whereas the diffraction limit is the maximum resolution ...
The add segment of the lens for near vision is the D-shaped area. A bifocal is a lens with two sections, separated by a line (see image to the right). Generally, the upper part of the lens is used for distance vision, while the lower segment is used for near vision. The area of the lens that caters to near vision is called the add segment.
Humphrey field analyser ( HFA) is a tool for measuring the human visual field that is commonly used by optometrists, orthoptists and ophthalmologists, particularly for detecting monocular visual field. [ 1] The results of the analyser identify the type of vision defect. Therefore, it provides information regarding the location of any disease ...
Abbe condensers are difficult to use for magnifications of above 400X, as the aplanatic cone is only representative of a numerical aperture (NA) of 0.6. This condenser is composed of two lenses, a plano-convex lens somewhat larger than a hemisphere and a large bi-convex lens serving as a collecting lens to the first.
Finally, the retailer's optical department also offers options that are important to corrective eyewear buyers, including: HD progressive and polarized lenses. Transitions photochromic lenses ...