Search results
Results from the WOW.Com Content Network
Although Excel nominally works with 8-byte numbers by default, VBA has a variety of data types. The Double data type is 8 bytes, the Integer data type is 2 bytes, and the general purpose 16 byte Variant data type can be converted to a 12 byte Decimal data type using the VBA conversion function CDec. [12]
Conversion of the fractional part: Consider 0.375, the fractional part of 12.375. To convert it into a binary fraction, multiply the fraction by 2, take the integer part and repeat with the new fraction by 2 until a fraction of zero is found or until the precision limit is reached which is 23 fraction digits for IEEE 754 binary32 format.
160 bits (20 bytes) – maximum key length of the SHA-1, standard Tiger (hash function), and Tiger2 cryptographic message digest algorithms 2 8: 256 bits (32 bytes) – minimum key length for the recommended strong cryptographic message digests as of 2004 – size of an AVX2 vector register, present on newer x86-64 CPUs 2 9: 512 bits (64 bytes)
A variable-length quantity (VLQ) is a universal code that uses an arbitrary number of binary octets (eight-bit bytes) to represent an arbitrarily large integer. A VLQ is essentially a base-128 representation of an unsigned integer with the addition of the eighth bit to mark continuation of bytes. VLQ is identical to LEB128 except in endianness ...
In a move or convert operation, zero extension refers to setting the high bits of the destination to zero, rather than setting them to a copy of the most significant bit of the source. If the source of the operation is an unsigned number, then zero extension is usually the correct way to move it to a larger field while preserving its numeric ...
The register width of a processor determines the range of values that can be represented in its registers. Though the vast majority of computers can perform multiple-precision arithmetic on operands in memory, allowing numbers to be arbitrarily long and overflow to be avoided, the register width limits the sizes of numbers that can be operated on (e.g., added or subtracted) using a single ...
However, on modern standard computers (i.e., implementing IEEE 754), one may safely assume that the endianness is the same for floating-point numbers as for integers, making the conversion straightforward regardless of data type. Small embedded systems using special floating-point formats may be another matter, however.
The INT3 instruction is a one-byte-instruction defined for use by debuggers to temporarily replace an instruction in a running program in order to set a code breakpoint. The more general INT XXh instructions are encoded using two bytes. This makes them unsuitable for use in patching instructions (which can be one byte long); see SIGTRAP.