In functional safety a safety instrumented system (SIS) is an engineered set of hardware and software controls which provides a protection layer that shuts down a chemical, nuclear, electrical, or mechanical system, or part of it, if a hazardous condition is detected.
An SIS is composed of a separate and independent combination of sensors, logic solvers, final elements, and support systems that are designed and managed to achieve a specified safety integrity level (SIL). An SIS may implement one or more safety instrumented functions (SIFs), which are designed and implemented to address a specific process ...
IEC 61508 is an international standard published by the International Electrotechnical Commission (IEC) consisting of methods on how to apply, design, deploy and maintain automatic protection systems called safety-related systems.
The technical report also defines the two metrics that define the effectiveness of fire and gas systems (as opposed to the single metric of safety integrity level (SIL) that is employed for safety instrumented systems (SIS)). These two metrics are coverage and safety availability. The coverage of a fire and gas detection array is defined in two ...
A high-integrity pressure protection system (HIPPS) is a type of safety instrumented system (SIS) designed to prevent over-pressurization of a plant, such as a chemical plant or oil refinery. The HIPPS will shut off the source of the high pressure before the design pressure of the system is exceeded, thus preventing loss of containment through ...
These lead to such erroneous statements as the tautology "This system is a SIL N system because the process adopted during its development was the standard process for the development of a SIL N system", or use of the SIL concept out of context such as "This is a SIL 3 heat exchanger" or "This software is SIL 2". According to IEC 61508, the SIL ...
Although functionally separate, process control and shutdown systems are usually interfaced under one system, called an integrated control and safety system (ICSS). Shutdown systems typically use equipment that is SIL 2 certified as a minimum, whereas control systems can start with SIL 1. SIL applies to both hardware and software requirements ...
A cyber PHA or cyber HAZOP is a safety-oriented methodology to conduct a cybersecurity risk assessment for an industrial control system (ICS) or safety instrumented system (SIS). It is a systematic, consequence-driven approach that is based upon industry standards such as ISA 62443-3-2 , ISA TR84.00.09, ISO/IEC 27005 :2018, ISO 31000 :2009 and ...