Search results
Results from the WOW.Com Content Network
A depressurization system comprises an actuated valve and a restriction orifice. The BDV valve is normally held in the closed position but opens on demand or on failure of the actuator. A restriction orifice (RO) downstream of the BDV is sized to achieve the desired blowdown rate. A locked-open valve may be located downstream of the orifice.
A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.
Bolt Shut-off Nozzle type BHP - pneumatic or hydraulic actuation. A shut-off bolt, positioned perpendicular to the melt channel moves up and down according to actuation, and thus shuts off/opens the melt flow. This nozzle type has a single melt channel. It therefore does not require rerouting of the melt around the shut-off mechanism.
An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes. [1] They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system. [ 2 ]
This means that they are installed as a component of the completion string and run in during completion. Retrieving the valve, should it malfunction, requires a workover. The full name for this most common type of downhole safety valve is a Tubing Retrievable Surface Controlled Sub-Surface Valve, shortened in completion diagrams to TRSCSSV.
Ordinary valves can have many ports and fluid paths. A 2-way valve, for example, has 2 ports; if the valve is open, then the two ports are connected and fluid may flow between the ports; if the valve is closed, then ports are isolated. If the valve is open when the solenoid is not energized, then the valve is termed normally open (N.O.).
PFD avg = [(1-PTC)×λ D ×(TI FC /2)] + [PTC×λ D ×(TI PST /2)] Where: PTC = Proof test coverage of the partial stroke test. λ D = The dangerous failure rate of the safety function. TI FC = The full closure interval, i.e. how often the valve must be full closed for testing. TI PST = The partial stroke test interval.
Unlike a ball valve, the disc is always present within the flow, so it induces a pressure drop, even when open. A butterfly valve is from a family of valves called quarter-turn valves. In operation, the valve is fully open or closed when the disc is rotated a quarter turn. The "butterfly" is a metal disc mounted on a rod. When the valve is ...