My Bryant Plus 90 gas furnace will not fire up. The blower motor is running but the fire box is not igniting. I remember from last year, a tech cleared the condensation drain and made adjustments to the flame. I'm starting the heater for the first time and the fire box will not ignite.
Customer: I need a new blower motor for a Bryant Plus 90i furnace. I believe it is a 1/2 HP motor. It was just replace under 2 years ago but a tech said I need a new one. I just need a model number so I can order online. The current motor is a GE 3.0 ECM motor but I need to ensure I have the exact model for this Carrier/Bryant furnace.
Customer: Need to wire digital thermostat to a Bryant Plus 90 furnace and an A/C unit. A/C unit has a red and white wire, Bryant has a Green, Yellow, White, Red, and Blue wire. Thermostat has W, Y, G, O, Rc, R, B, C (honeywell TH3110D1008).
Customer: My ,Bryant plus 90, furnace stopped igniting tonight. I am getting a 34 code and need help in figuring out how to fix it. I am getting a 34 code and need help in figuring out how to fix it. Answered by gotoman for ac in 53 mins 12 years ago
Bryant 90 Plus 350mav. Code 34. I put in a new flame sensor and pressure switch because of other posts on the net. I still have the same problem as before. It ignites and stays lit anywhere from 5 seconds to 1 minute. And has ran to warm the house up for a full cycles sometimes when I shut power off to the furnace and turn it back on.
We have a Plus 90 furnace that needs the lower heating unit replaced, which appears to be covered under manufacturer BillyHvac Endorsed for unlimited heating, cooling, oil burners, boilers, refrigeration, hydronics
My Bryant 90 Plus gas furnace model - 399AAV failed to light and produce heat. No problems with blower all summer since it is connected to the CAC system. Switched over to test the heating system and while blower comes on it only lasts 3 minutes and shuts off. System seems to “try” and ignite but cuts out after three (3) minutes also.
Customer: Bryant Plus 90i furnace fault code 42 "inducer outside valid speed range". I noticed vibration in the motor and fan and removed the unit and cleaned build up on the fan thinking it was imbalanced due to the build up.
Customer: Bryant Plus 90 propane furnace keeps tripping roll out switch, Took the combustion box apart, cleaned the burner tubes (phenolic ends had several plugged holes), replaced the flame proof and hot surface ignitor (I had one so did it while it was taken apart), cleaned the box, removed all rust and crap, used a small nozzle brush to clean each of the nozzles then reassembled.
We have a Plus 90 furnace that needs the lower heating unit replaced, which appears to be covered under manufacturer BillyHvac Endorsed for unlimited heating, cooling, oil burners, boilers, refrigeration, hydronics