Using contrast material can also help to obtain functional information about tissues. Often, images are taken both with and without radiocontrast. CT images are called precontrast or native-phase images before any radiocontrast has been administered, and postcontrast after radiocontrast administration. [2]
The mask image is simply an image of the same area before the contrast is administered. The radiological equipment used to capture this is usually an X-ray image intensifier, which then keeps producing images of the same area at a set rate (1 to 7.5 frames per second). Each subsequent image gets the original "mask" image subtracted out.
Original file (3,264 × 2,448 pixels, file size: 1.71 MB, MIME type: image/jpeg) This is a file from the Wikimedia Commons. ... Contrast CT; Global file usage.
Abdominal imaging is associated with many potential uses for the different phases of contrast CT.The majority of abdominal and pelvic CT's can be performed using a single-phase, but the evaluation of some tumor types (hepatic/pancreatic/renal), the urinary collecting system, and trauma patients among others, may be best performed with multiple phases.
Volume rendered CT scan of abdominal and pelvic blood vessels. CT angiography is a contrast CT where images are taken with a certain delay after injection of radiocontrast material. The contrast material is radiodense causing it to light up brightly within the blood vessels of interest. In order for the CT scanner to be able to scan the correct ...
A typical coronary CT calcium scan is done without the use of radiocontrast agent but it can also be performed using contrast-enhanced images as well, such as in coronary CT angiography. [4] The exam is best performed with cardiac gating to eliminate motion but can also be estimated in the presence of motion.
Iodinated contrast contains iodine.It is the main type of radiocontrast used for intravenous administration.Iodine has a particular advantage as a contrast agent for radiography because its innermost electron ("k-shell") binding energy is 33.2 keV, similar to the average energy of x-rays used in diagnostic radiography.
A PCD can implement more than two energy thresholds with a higher degree of separation than what is possible to achieve in dual-energy CT. This improvement in energy resolution translates to higher contrast-to-noise ratio in the image, in particular in contrast-enhanced and material-selective images.