Search results
Results from the WOW.Com Content Network
Air density, like air pressure, decreases with increasing altitude. It also changes with variations in atmospheric pressure, temperature and humidity. At 101.325 kPa (abs) and 20 °C (68 °F), air has a density of approximately 1.204 kg/m 3 (0.0752 lb/cu ft), according to the International Standard Atmosphere (ISA).
For example, in the range of normal temperatures, air at 68 °F (20 °C) and 50% relative humidity will become saturated if cooled to 50 °F (10 °C), its dew point, and 41 °F (5 °C) air at 80% relative humidity warmed to 68 °F (20 °C) will have a relative humidity of only 29% and feel dry.
using Plots # Saturated water vapor pressure [Pa] # See Ham, 2005. Useful Equations and Tables in Micrometeorology function water_vapor_saturated_pressure (Ta, P) Ta = Ta-273.15 es = (1.0007 + (3.46e-5 * (P / 1e3))) * 0.61121 * exp ((17.502 * Ta) / (Ta + 240.97)) * 1e3 return es end function water_vapor_density (e, Tair) Rs_v = 461.5 # J/(kg.K) specific gas constant for water vapor ρv = e ...
The density altitude is the altitude relative to standard atmospheric conditions at which the air density would be equal to the indicated air density at the place of observation. In other words, the density altitude is the air density given as a height above mean sea level .
When the air is cooled below the dew point, its moisture capacity is reduced and airborne water vapor will condense to form liquid water known as dew. [2] When this occurs through the air's contact with a colder surface, dew will form on that surface. [3] The dew point is affected by the air's humidity. The more moisture the air contains, the ...
Diagram showing displacement of the Sun's image at sunrise and sunset Comparison of inferior and superior mirages due to differing air refractive indices, n. Atmospheric refraction is the deviation of light or other electromagnetic wave from a straight line as it passes through the atmosphere due to the variation in air density as a function of height. [1]
Using the conditions from the previous example, the relative humidity at a different dry bulb temperatures can be found along the horizontal humidity ratio line of 0.0126, either in kg water per kg dry air or pounds water per pound dry air. A common variation of this problem is determining the final humidity of air leaving an air conditioner ...
The LCL can be either computed or determined graphically using standard thermodynamic diagrams such as the skew-T log-P diagram or the tephigram.Nearly all of these formulations make use of the relationship between the LCL and the dew point, which is the temperature to which an air parcel needs to be cooled isobarically until its RH just reaches 100%.