  1. Results from the WOW.Com Content Network
  2. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Poorly insulated walls: 2 W/(m 2 ⋅K) Well-insulated floors: 0.2 W/(m 2 ⋅K) Poorly insulated floors: 1.0 W/(m 2 ⋅K) In practice the thermal transmittance is strongly affected by the quality of workmanship and if insulation is fitted poorly, the thermal transmittance can be considerably higher than if insulation is fitted well [3]

  3. Vacuum insulated panel - Wikipedia

    en.wikipedia.org/wiki/Vacuum_insulated_panel

    This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...

  4. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  5. Building insulation - Wikipedia

    en.wikipedia.org/wiki/Building_insulation

    The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.

  6. Dynamic insulation - Wikipedia

    en.wikipedia.org/wiki/Dynamic_insulation

    Dynamic insulation works best with a good thickness of insulation so taking 200 mm of cellulose insulation (k = 0.04 W/m °C) the dynamic U value for an air flow of 0.31 mm/s is calculated using equation above to be 0.066 W/m 2 °C. If a lower dynamic U-value is required then a material with lower air permeability than fibreboard would need to ...

  7. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]