enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Characteristic impedance - Wikipedia

    en.wikipedia.org/wiki/Characteristic_impedance

    Characteristic impedance is determined by the geometry and materials of the transmission line and, for a uniform line, is not dependent on its length. The SI unit of characteristic impedance is the ohm. The characteristic impedance of a lossless transmission line is purely real, with no reactive component (see below).

  3. Transmission line - Wikipedia

    en.wikipedia.org/wiki/Transmission_line

    Impedance (Z) parameter may defines by applying a fixed current into one port (I1) of a transmission line with the other port open and measuring the resulting voltage on each port (V1, V2) [8] [9] and computing the impedance parameter Z11 is V1/I1, and the impedance parameter Z12 is V2/I1. Since transmission lines are electrically passive and ...

  4. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    In many cases, there is a need to use the same circuit to match a broad range of load impedance and thus simplify the circuit design. This issue was addressed by the stepped transmission line, [1] where multiple, serially placed, quarter-wave dielectric slugs are used to vary a transmission line's characteristic impedance. By controlling the ...

  5. Telegrapher's equations - Wikipedia

    en.wikipedia.org/wiki/Telegrapher's_equations

    Equivalent circuit of an unbalanced transmission line (such as coaxial cable) where: 2/Z o is the trans-admittance of VCCS (Voltage Controlled Current Source), x is the length of transmission line, Z(s) ≡ Z o (s) is the characteristic impedance, T(s) is the propagation function, γ(s) is the propagation "constant", s ≡ j ω, and j 2 ≡ −1.

  6. Stub (electronics) - Wikipedia

    en.wikipedia.org/wiki/Stub_(electronics)

    Stubs can match a load impedance to the transmission line characteristic impedance. The stub is positioned a distance from the load. This distance is chosen so that at that point, the resistive part of the load impedance is made equal to the resistive part of the characteristic impedance by impedance transformer action of the length of the main ...

  7. Input impedance - Wikipedia

    en.wikipedia.org/wiki/Input_impedance

    To minimize reflections, the characteristic impedance of the transmission line and the impedance of the load circuit have to be equal (or "matched"). If the impedance matches, the connection is known as a matched connection, and the process of correcting an impedance mismatch is called impedance matching. Since the characteristic impedance for ...

  8. Distributed-element model - Wikipedia

    en.wikipedia.org/wiki/Distributed-element_model

    Fig.1 Transmission line. The distributed-element model applied to a transmission line. In electrical engineering, the distributed-element model or transmission-line model of electrical circuits assumes that the attributes of the circuit (resistance, capacitance, and inductance) are distributed continuously throughout the material of the circuit.

  9. Performance and modelling of AC transmission - Wikipedia

    en.wikipedia.org/wiki/Performance_and_modelling...

    The characteristic impedance or surge impedance (usually written Z 0) of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line; that is, a wave travelling in one direction in the absence of reflections in the other direction. Alternatively and equivalently it can be defined ...