Ads
related to: coaxial line impedance calculator current
Search results
Results from the WOW.Com Content Network
The characteristic impedance () of an infinite transmission line at a given angular frequency is the ratio of the voltage and current of a pure sinusoidal wave of the same frequency travelling along the line. This relation is also the case for finite transmission lines until the wave reaches the end of the line.
Equivalent circuit of an unbalanced transmission line (such as coaxial cable) where: 2/Z o is the trans-admittance of VCCS (Voltage Controlled Current Source), x is the length of transmission line, Z(s) ≡ Z o (s) is the characteristic impedance, T(s) is the propagation function, γ(s) is the propagation "constant", s ≡ j ω, and j 2 ≡ −1.
A transmission line is drawn as two black wires. At a distance x into the line, there is current I(x) travelling through each wire, and there is a voltage difference V(x) between the wires. If the current and voltage come from a single wave (with no reflection), then V(x) / I(x) = Z 0, where Z 0 is the characteristic impedance of the line.
A time-domain reflectometer; an instrument used to locate the position of faults on lines from the time taken for a reflected wave to return from the discontinuity.. A signal travelling along an electrical transmission line will be partly, or wholly, reflected back in the opposite direction when the travelling signal encounters a discontinuity in the characteristic impedance of the line, or if ...
SWR is used as a measure of impedance matching of a load to the characteristic impedance of a transmission line carrying radio frequency (RF) signals. This especially applies to transmission lines connecting radio transmitters and receivers with their antennas, as well as similar uses of RF cables such as cable television connections to TV receivers and distribution amplifiers.
The most widely used types of feed line are coaxial cable, twin-lead, ladder line, and at microwave frequencies, waveguide. Particularly with a transmitting antenna, the feed line is a critical component that must be adjusted to work correctly with the antenna and transmitter. Each type of transmission line has a specific characteristic impedance.
L networks for narrowband matching a source or load impedance Z to a transmission line with characteristic impedance Z 0. X and B may each be either positive (inductor) or negative (capacitor). If Z/Z 0 is inside the 1+jx circle on the Smith chart (i.e. if Re(Z/Z 0)>1), network (a) can be used; otherwise network (b) can be used. [2]
Coaxial cable, or coax (pronounced / ˈ k oʊ. æ k s /), is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield, with the two separated by a dielectric (insulating material); many coaxial cables also have a protective outer sheath or jacket.
Ads
related to: coaxial line impedance calculator current