American building codes started classifying vapor retarders in the 2007 IRC supplement. They are Class I <0.1 perm, Class II 0.1 - 1 perm and Class III 1-10 perm when tested in accordance with the ASTM E96 desiccant, dry cup or method A. [ 1 ] Vapor-retarding materials are generally categorized as:
Part 1-California Administrative Code; Part 2-California Building Code; Part 2.5-California Residential Code; Part 3-California Electrical Code; Part 4-California Mechanical Code; Part 5-California Plumbing Code; Part 6-California Energy Code (this section is commonly known as “Title 24” in the construction trade) [3] Part 7- Reserved
He consults regularly on building code and industry standards. [1] Widely known for his "Perfect Wall" concept, Lstiburek identified four key control layers within the building envelope (bulk water, air, thermal and vapor) critical to a building's behavior, long-term performance, and viability. He is a proponent of understanding the concepts ...
Open-cell foam is porous, allowing water vapor and liquid water to penetrate the insulation. Closed-cell foam is non-porous, and not moisture-penetrable, thereby effectively forming a semi-permeable vapor barrier. (N.B., vapor barriers are usually required by the Building Codes, regardless of the type of insulation used.
The 2009 International Residential Code embodies more sophisticated rules to guide the choice of insulation on the exterior of new homes, which can be applied when retrofitting older homes. A vapor-permeable building wrap on the outside of the original wall helps keep the wind out and allows the wall assembly to dry to the exterior.
In order to achieve these objectives, all building enclosure systems must include a solid structure, a drainage plane, an air barrier, a thermal barrier, and may include a vapor barrier. Moisture control (e.g. damp proofing) is essential in all climates, but cold climates and hot-humid climates are especially demanding. [8]
There are two industry standards for measuring moisture vapor emissions in concrete: calcium chloride testing (ASTM F1869) and relative humidity testing (ASTM F2170). [3] Epoxy moisture control systems can be used when these tests determine that the moisture vapor emissions need to be remediated in order to install the selected floor covering ...
It is important to realise a single R-value or U-value does not take into account the quality of construction or local environmental factors for each building. Construction quality issues can include inadequate vapor barriers and problems with draft-proofing. In addition, the properties and density of the insulation material itself are critical.