A psychrometric chart is a graph of the thermodynamic parameters of moist air at a constant pressure, often equated to an elevation relative to sea level. The ASHRAE-style psychrometric chart, shown here, was pioneered by Willis Carrier in 1904. [10] It depicts these parameters and is thus a graphical equation of state. The parameters are:
English: This psychrometric chart represents the acceptable combination of air temperature and humidity values, according to the PMV/PPD method in the ASHRAE 55-2010 Standard. The comfort zone in blue represents the 90% of acceptability, which means the conditions between -0.5 and +0.5 PMV, or PPD < 10%.
The CBE Thermal Comfort Tool for ASHRAE 55 [9] allows users to input the six comfort parameters to determine whether a certain combination complies with ASHRAE 55. The results are displayed on a psychrometric or a temperature-relative humidity chart and indicate the ranges of temperature and relative humidity that will be comfortable with the ...
ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy is an American National Standard published by ASHRAE that establishes the ranges of indoor environmental conditions to achieve acceptable thermal comfort for occupants of buildings. It was first published in 1966, and since 2004 has been updated every three to six years.
The dry-bulb temperature is one of the main input for thermal comfort calculations and it is also used for assessing the heat transfer by convection. The dry-bulb temperature is an important variable in psychrometrics , being the horizontal axis of a psychrometric chart .
Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...
Figure 2: On a standard psychrometric chart, the air flow state points of the Cromer cycle are shown. The psychrometric process of the air passing through the system with four state points is shown on the psychrometric chart of Figure 2 as 1, 2, 3 and 4. The state points of the air are also depicted in Figure 1.
English: This chart represents the acceptable combination of air temperature and humidity values, according to the PMV/PPD method in the ASHRAE 55-2010 Standard. The representation is made on a temperature-relative humidity, instead of a standard psychrometric chart.