Left direct pupillary reflex is the left pupil's response to light entering the left eye, the ipsilateral eye. Left consensual pupillary reflex is the left pupil's indirect response to light entering the right eye, the contralateral eye. Right direct pupillary reflex is the right pupil's response to light entering the right eye, the ipsilateral ...
For an abnormal result, based on where the light lands on the cornea, the examiner can detect if there is an exotropia (abnormal eye is turned out), esotropia (abnormal eye is turned in), hypertropia (abnormal eye higher than the normal one) or hypotropia (abnormal eye is lower than the normal one).
The pupillary reflex results in the pupil constricting (left) and dilating (right) These include the pupillary light reflex and accommodation reflex . Although the pupillary response , in which the pupil dilates or constricts due to light is not usually called a "reflex", it is still usually considered a part of this topic.
Therefore, using an eyecup is even more necessary. Overall, using an eyecup helps ensure precise measurements of the pupillary light reflex. Numeric scales allow for a more rigorous interpretation and classification of the pupil response and are a primary feature of both hardware and software based pupillometers.
The Neurological Pupil index, or NPi, is an algorithm developed by NeurOptics, Inc., that removes subjectivity from the pupillary evaluation. A patient's pupil measurement (including variables such as size, latency, constriction velocity, dilation velocity, etc.) is obtained using a pupillometer, and the measurement is compared against a normative model of pupil reaction to light and ...
When the optic nerve is damaged, the sensory (afferent) stimulus sent to the midbrain is reduced. The pupil, responding less vigorously, dilates from its prior constricted state when the light is moved away from the unaffected eye and towards the affected eye. This response is a relative afferent pupillary defect (or Marcus Gunn pupil). [1]
While moving the streak or spot of light through the pupil across the retina, the examiner observes the relative movement of the reflex or manually places lenses over the eye (using a phoropter or trial frame and trial lenses) to "neutralize" the reflex. [2] Static retinoscopy is a type of retinoscopy used in determining a patient's refractive ...
Many automated pupilometers can also function as a type of pupil response monitor by measuring pupil dilation in response to a visual stimulus.. In ophthalmology, a pupillary response to light is differentiated from a pupillary response to focus (i.e. pupils may constrict on near focus, as with the Argyll Robertson pupil) in the diagnosis of tertiary syphilis.