[15] [16] For example, to maintain a 15 °C temperature in a certain dwelling about 3.0 kW of heating are required at 0 ACH (no heat loss due to warmed air leaving the dwelling, instead heat is lost due to conduction or radiation), 3.8 kW at 1 ACH and 4.5 kW are required at 2 ACH. [15]
Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).
Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.
Air returns from the room at ceiling level or the maximum allowable height above the occupied zone. [1] The UFAD system takes advantage of the thermal plume and stratification phenomenon: the conditioned air is supplied directly to the occupied zone (OZ). The thermal plumes generated by the occupants and other heat sources introduce the ...
A round diffuser in an HVAC system. Diffusers are very common in heating, ventilating, and air-conditioning systems. [3] Diffusers are used in both all-air and air-water HVAC systems, as part of room air distribution subsystems, and serve several purposes: To deliver both conditioning and ventilating air
During winter months, for example, an air conditioning register can be closed to prevent cold air from being pulled from the room. This allows the hot air to mix more completely with the cold air in the room, improving the efficiency of the HVAC system. [7] (The return should be efficient enough to draw off the cooler air.) [10] [11]
The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h.
They conclude 15% of the space conditioning energy use can be saved in the UK context going from 11.5 m 3 /(m 2 ·h) @50 Pa (average current value) down to 5 m 3 /(m 2 ·h) @50 Pa (achievable). Given its impacts on heat losses, good building airtightness may allow installation of smaller heating and cooling capacities.