enow.com Web Search

  1. Ad

    related to: convert kilowatt to mw heat chart for propane heaters residential

Search results

  1. Results from the WOW.Com Content Network
  2. Module:Convert/documentation/conversion data - Wikipedia

    en.wikipedia.org/wiki/Module:Convert/...

    The conversion procedure for some units (for example, the Mach unit of speed) are built into Module:Convert as they are too complex to be specified in a table. That is indicated by entering a code (which must be the same as used in the module) in the Extra column.

  3. Energy conversion efficiency - Wikipedia

    en.wikipedia.org/wiki/Energy_conversion_efficiency

    For example, an ideal fuel cell operating at a temperature of 25 °C having gaseous hydrogen and gaseous oxygen as inputs and liquid water as the output could produce a theoretical maximum amount of electrical energy of 237.129 kJ (0.06587 kWh) per gram mol (18.0154 gram) of water produced and would require 48.701 kJ (0.01353 kWh) per gram mol ...

  4. Heating degree day - Wikipedia

    en.wikipedia.org/wiki/Heating_degree_day

    Heating degree day (HDD) is a measurement designed to quantify the demand for energy needed to heat a building. HDD is derived from measurements of outside air temperature . The estimated average heating energy requirements for a given building at a specific location are considered to be directly proportional to the number of HDD at that location.

  5. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    Heating seasonal performance factor (HSPF) is a term used in the heating and cooling industry. HSPF is specifically used to measure the efficiency of air source heat pumps. HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1] [2] It therefore has units of BTU ...

  6. Thermal efficiency - Wikipedia

    en.wikipedia.org/wiki/Thermal_efficiency

    In the United States, in everyday usage the SEER is the more common measure of energy efficiency for cooling devices, as well as for heat pumps when in their heating mode. For energy-conversion heating devices their peak steady-state thermal efficiency is often stated, e.g., 'this furnace is 90% efficient', but a more detailed measure of ...

  7. Power plant efficiency - Wikipedia

    en.wikipedia.org/wiki/Power_plant_efficiency

    For example, if using Btu/kWh, use a conversion factor of 3,412 Btu per kWh to calculate the efficiency factor. For example, if the heat rate is 10,500 Btu/kWh, the efficiency is 32.5% (since 3,412 Btu / 10,500 Btu = 32.5%). The higher the heat rate (i.e. the more energy input that is required to produce one unit of electric output), the lower ...

  8. Gas-fired power plant - Wikipedia

    en.wikipedia.org/wiki/Gas-fired_power_plant

    The 605 MW General Electric 9HA achieved a 62.22% efficiency rate with temperatures as high as 1,540 °C (2,800 °F). [4] For 2018, GE offers its 826 MW HA at over 64% efficiency in combined cycle due to advances in additive manufacturing and combustion breakthroughs, up from 63.7% in 2017 orders and on track to achieve 65% by the early 2020s ...

  9. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    The heat transfer coefficient has SI units in watts per square meter per kelvin (W/(m 2 K)). The overall heat transfer rate for combined modes is usually expressed in terms of an overall conductance or heat transfer coefficient, U. In that case, the heat transfer rate is: ˙ = where (in SI units):

  1. Ad

    related to: convert kilowatt to mw heat chart for propane heaters residential