enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Beer–Lambert law - Wikipedia

    en.wikipedia.org/wiki/Beer–Lambert_law

    Absorbance within range of 0.2 to 0.5 is ideal to maintain linearity in the Beer–Lambert law. If the radiation is especially intense, nonlinear optical processes can also cause variances. The main reason, however, is that the concentration dependence is in general non-linear and Beer's law is valid only under certain conditions as shown by ...

  3. Henderson–Hasselbalch equation - Wikipedia

    en.wikipedia.org/wiki/Henderson–Hasselbalch...

    The Henderson–Hasselbalch equation can be used to model these equilibria. It is important to maintain this pH of 7.4 to ensure enzymes are able to work optimally. [10] Life threatening Acidosis (a low blood pH resulting in nausea, headaches, and even coma, and convulsions) is due to a lack of functioning of enzymes at a low pH. [10]

  4. Molar absorption coefficient - Wikipedia

    en.wikipedia.org/wiki/Molar_absorption_coefficient

    The SI unit of molar absorption coefficient is the square metre per mole (m 2 /mol), but in practice, quantities are usually expressed in terms of M −1 ⋅cm −1 or L⋅mol −1 ⋅cm −1 (the latter two units are both equal to 0.1 m 2 /mol). In older literature, the cm 2 /mol is sometimes used; 1 M −1 ⋅cm −1 equals 1000 cm 2 /mol.

  5. Absorbance - Wikipedia

    en.wikipedia.org/wiki/Absorbance

    Absorbance is defined as "the logarithm of the ratio of incident to transmitted radiant power through a sample (excluding the effects on cell walls)". [1] Alternatively, for samples which scatter light, absorbance may be defined as "the negative logarithm of one minus absorptance, as measured on a uniform sample". [2]

  6. Nucleic acid quantitation - Wikipedia

    en.wikipedia.org/wiki/Nucleic_acid_quantitation

    The blank solution should be the same pH and of a similar ionic strength as the sample solution. Example: using water for the blank measurement for samples dissolved in TE may result in low 260/230 ratios. A260/A280 Residual phenol or other reagent associated with the extraction protocol. A very low concentration (< 10 ng/μL) of nucleic acid.

  7. Ion speciation - Wikipedia

    en.wikipedia.org/wiki/Ion_speciation

    Speciation of ions refers to the changing concentration of varying forms of an ion as the pH of the solution changes. [1]The ratio of acid, AH and conjugate base, A −, concentrations varies as the difference between the pH and the pK a varies, in accordance with the Henderson-Hasselbalch equation.

  8. Colorimeter (chemistry) - Wikipedia

    en.wikipedia.org/wiki/Colorimeter_(chemistry)

    A colorimeter is a device used in colorimetry that measures the absorbance of particular wavelengths of light by a specific solution. [1] [2] It is commonly used to determine the concentration of a known solute in a given solution by the application of the Beer–Lambert law, which states that the concentration of a solute is proportional to the absorbance.

  9. Isosbestic point - Wikipedia

    en.wikipedia.org/wiki/Isosbestic_point

    The spectra of basic, acid and intermediate pH solutions are shown. The analytical concentration of the dye is the same in all solutions. In spectroscopy, an isosbestic point is a specific wavelength, wavenumber or frequency at which the total absorbance of a sample does not change during a chemical reaction or a physical change of the sample ...