Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage. [citation needed] Extra ground connections on a neutral conductor may bypass the protection provided by a ground-fault circuit interrupter. Signal circuits that ...
This is true even if circuit 2 is turned off. Although ground loops occur most often in the ground conductors of electrical equipment, similar loops can occur wherever two or more circuits share a common current path, which can cause a similar problematic voltage drop along the conductor if enough current flows.
An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a "ground" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground ...
NEC 2008 400.22(f) allows surface marking with ridged, grooves or white stripes on the surface of lamp cord. With transparent cord the hot wire is copper colored, and the neutral is silver colored. Grounding wire of circuit may be bare or identified insulated wire of green or green having yellow stripes. All metallic systems in a building are ...
The neutral is theoretically at 0 V potential, as any grounded object, but current flows on the neutral back to the source, somewhat elevating the neutral voltage. NEV is the product of current flowing on the neutral and the finite, non-zero impedance of the neutral conductor between a given point and its source, often a distant electrical ...
Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).
For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only ...
In electrical engineering, earth potential rise (EPR), also called ground potential rise (GPR), occurs when a large current flows to earth through an earth grid impedance. The potential relative to a distant point on the Earth is highest at the point where current enters the ground, and declines with distance from the source.