enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage. [citation needed] Extra ground connections on a neutral conductor may bypass the protection provided by a ground-fault circuit interrupter. Signal circuits that ...

  3. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    This is true even if circuit 2 is turned off. Although ground loops occur most often in the ground conductors of electrical equipment, similar loops can occur wherever two or more circuits share a common current path, which can cause a similar problematic voltage drop along the conductor if enough current flows.

  4. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a "ground" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground ...

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    NEC 2008 400.22(f) allows surface marking with ridged, grooves or white stripes on the surface of lamp cord. With transparent cord the hot wire is copper colored, and the neutral is silver colored. Grounding wire of circuit may be bare or identified insulated wire of green or green having yellow stripes. All metallic systems in a building are ...

  6. Stray voltage - Wikipedia

    en.wikipedia.org/wiki/Stray_voltage

    The neutral is theoretically at 0 V potential, as any grounded object, but current flows on the neutral back to the source, somewhat elevating the neutral voltage. NEV is the product of current flowing on the neutral and the finite, non-zero impedance of the neutral conductor between a given point and its source, often a distant electrical ...

  7. Floating ground - Wikipedia

    en.wikipedia.org/wiki/Floating_ground

    Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).

  8. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only ...

  9. Earth potential rise - Wikipedia

    en.wikipedia.org/wiki/Earth_potential_rise

    In electrical engineering, earth potential rise (EPR), also called ground potential rise (GPR), occurs when a large current flows to earth through an earth grid impedance. The potential relative to a distant point on the Earth is highest at the point where current enters the ground, and declines with distance from the source.