Thus a meter with a 50 μA movement will have a "sensitivity" of 20,000 Ω/V. "Per volt" refers to the fact that the impedance the meter presents to the circuit under test will be 20,000 Ω multiplied by the full-scale voltage to which the meter is set. For example, if the meter is set to a range of 300 V full scale, the meter's impedance will ...
Electricity meter: Measures the amount of energy dissipated ESR meter: Measures the equivalent series resistance of capacitors Frequency counter: Measures the frequency of the current Leakage tester: Measures leakage across the plates of a capacitor LCR meter: Measures the inductance, capacitance and resistance of a component Megger tester
For example, IEC 60027, and Letter Symbols in Electrical Technology. Here are tables of widely accepted symbols. They are meant to be a guideline: Using the same symbols for the same things in different articles will increase their consistency, making them easier to understand and to improve.
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...
Multistation watt-hour meter test board 1942 Resistive load box 1950 Cable fault locator 1951 Protective relay test set 1953 Partial discharge (Corona) detection system 1968 Portable digital multimeter 1979 Digital line earth loop impedance tester 1985 Microprocessor-based high current test set 1989 Battery impedance test equipment (BITE) 1990
When testing power supply circuits, a high-impedance connection (that is, a nearly open-circuit fault such as a burned switch contact or wire joint) in the power path might still allow enough voltage/current through to register on a high-impedance digital voltmeter, but it probably can't actuate the solenoid voltmeter. For use with high ...
In electrical engineering, an electrical isolation test is a direct current (DC) or alternating current (AC) resistance test that is performed on sub-systems of an electronic system to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same ...
I and V sweeping—Sweep capabilities offer a way to test devices under a range of conditions with different source, delay and measure characteristics. These can include fixed level, linear/log and pulsed sweeps. On-board processor—Some SMUs further improve instrument integration, communication and test time by adding an on-board script ...