Search results
Results from the WOW.Com Content Network
A chase nipple is a short pipe fitting, which creates a path for wires between two electrical boxes. A chase nipple has male threads on one end only. The other end is a hexagon. The chase nipple passes through the knockouts of two boxes, and is secured by an internally threaded ring called a lock nut. [1] [2]
This fitting (also known as a "bungalow fitting" or a "cottage fitting") is a sanitary tee that allows two trap arms to be connected at the same level. A toilet is the main connection, with the option of a right or left-hand outlet to the 3" inlet with a choice of 1-1/2" or 2" in size.
In engineering, the Moody chart or Moody diagram (also Stanton diagram) is a graph in non-dimensional form that relates the Darcy–Weisbach friction factor f D, Reynolds number Re, and surface roughness for fully developed flow in a circular pipe. It can be used to predict pressure drop or flow rate down such a pipe.
A compression fitting 15 mm isolating valve. A compression fitting is a fitting used in plumbing and electrical conduit systems to join two tubes or thin-walled pipes together. . In instances where two pipes made of dissimilar materials are to be joined (most commonly PVC and copper), the fittings will be made of one or more compatible materials appropriate for the connect
Each fixture usually has a characteristic means of connection. Normal plumbing practice is to install a valve on each water supply line before the fixture, and this is most commonly termed a stop or "service valve". The water supply to some fixtures is cold water only (such as water closets and urinals). Most fixtures also have a hot water supply.
The half-angle (between the taper surface and the axis of the pipe) is arctan(1 ⁄ 32) ≈ 1.7899° ≈ 1° 47′. The standard for Nominal Pipe Size (often abbreviated NPS, which should not be confused with the abbreviation NPS for the straight thread form standard) is loosely related to the inside diameter of Schedule 40 series of sizes.
In the U.S., every plumbing fixture must also be coupled to the system's vent piping. [1] Without a vent, negative pressure can slow the flow of water leaving the system, resulting in clogs, or cause siphonage to empty a trap. The high point of the vent system (the top of its "soil stack") must be open to the exterior at atmospheric pressure.
The second standard, A-A-58092, [4] is a commercial grade which maintains the thickness requirement of MIL-T-27730A and adds a minimum density of 1.2 g/cm 3. [4] Relevant standards may vary between industries; tape for gas fittings (to UK gas regulations) is required to be thicker than that for water.