  1. Results from the WOW.Com Content Network
  2. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed ...

  3. Trickle vent - Wikipedia

    en.wikipedia.org/wiki/Trickle_vent

    The US Standard ASHRAE 62.1-2007: Ventilation for Acceptable Indoor Air Quality, only requires 4% of net floor area to be operable. This creates the potential for increased energy consumption where natural ventilation is provided by operable windows where supplemental air conditioning is provided, in addition to generally poor control over ventilation rates during hot summer or cold winter ...

  4. Passive ventilation - Wikipedia

    en.wikipedia.org/wiki/Passive_ventilation

    In order for ventilation to be effective, there must be exchange between outdoor air and room air. A common method for measuring ventilation effectiveness is to use a tracer gas. [6] The first step is to close all windows, doors, and openings in the space. Then a tracer gas is added to the air.

  5. Ventilative cooling - Wikipedia

    en.wikipedia.org/wiki/Ventilative_cooling

    Ventilative cooling is the use of natural or mechanical ventilation to cool indoor spaces. [1] The use of outside air reduces the cooling load and the energy consumption of these systems, while maintaining high quality indoor conditions; passive ventilative cooling may eliminate energy consumption.

  6. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...

  7. Passive cooling - Wikipedia

    en.wikipedia.org/wiki/Passive_cooling

    Passive cooling covers all natural processes and techniques of heat dissipation and modulation without the use of energy. [1] Some authors consider that minor and simple mechanical systems (e.g. pumps and economizers) can be integrated in passive cooling techniques, as long they are used to enhance the effectiveness of the natural cooling process. [7]