For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed ...
The US Standard ASHRAE 62.1-2007: Ventilation for Acceptable Indoor Air Quality, only requires 4% of net floor area to be operable. This creates the potential for increased energy consumption where natural ventilation is provided by operable windows where supplemental air conditioning is provided, in addition to generally poor control over ventilation rates during hot summer or cold winter ...
Ventilative cooling is the use of natural or mechanical ventilation to cool indoor spaces. [1] The use of outside air reduces the cooling load and the energy consumption of these systems, while maintaining high quality indoor conditions; passive ventilative cooling may eliminate energy consumption.
Mixed-mode ventilation is a hybrid approach to space conditioning that uses a combination of natural ventilation from operable windows (either manually or automatically controlled), and mechanical systems that include air distribution equipment and refrigeration equipment for cooling. A well-designed mixed-mode building begins with intelligent ...
The ventilation performance prediction provides the information regarding indoor air parameters in a room or a building even before the construction of buildings. [ 8 ] These air parameters are crucial for designing a comfortable indoor as well as a good integration of the building in the outdoor environment.
Clean air delivery rate (CADR) is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 30 cubic metres (1,000 cu ft) per minute and an efficiency of 50% has a CADR of 15 cubic metres (500 cu ft) per minute.
[10] [11] The equations apply only to buildings where air is both inside and outside the buildings. For buildings with one or two floors, h is the height of the building. For multi-floor, high-rise buildings, h is the distance from the openings at the neutral pressure level (NPL) of the building to either the topmost openings or the lowest ...
Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...