Heyrovský's Polarograph. Polarography is an electrochemical voltammetric technique that employs (dropping or static) mercury drop as a working electrode. In its most simple form polarography can be used to determine concentrations of electroactive species in liquids by measuring their mass-transport limiting currents.
Fluxgate sensors or saturable inductor current sensors work on the same measurement principle as Hall-effect-based current sensors: the magnetic field created by the primary current to be measured is detected by a specific sensing element. The design of the saturable inductor current sensor is similar to that of a closed-loop Hall-effect ...
Galvanic isolation is a principle of isolating functional sections of electrical systems to prevent current flow; no direct conduction path is permitted. [ 1 ] [ 2 ] Energy or information can still be exchanged between the sections by other means, such as capacitive , inductive , radiative , optical , acoustic , or mechanical coupling.
The application of a saturation eddy current technique depends on the permeability of the material, tube thickness, and diameter. [10] A method used for carbon steel tubing is remote field eddy current testing. This method is sensitive to general wall loss and not sensitive to small pits and cracks.
Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...
Measurements of current are taken as function of time and potential between the indicator and reference electrodes. [20] [21] Normal pulse voltammetry: An electrochemical technique that uses the same waveform as normal pulse polarography, but can be used to refer to waveforms of non-polarographic electrodes. [22] Differential pulse voltammetry
In addition, because concentration is proportional to current in a reversible, Nernstian system, the concentration of an unknown solution can be determined by generating a calibration curve of current vs. concentration. [14] In cellular biology it is used to measure the concentrations [clarification needed] in living organisms. [15]
An early D'Arsonval galvanometer showing magnet and rotating coil. A galvanometer is an electromechanical measuring instrument for electric current.Early galvanometers were uncalibrated, but improved versions, called ammeters, were calibrated and could measure the flow of current more precisely.