Search results
Results from the WOW.Com Content Network
Typical volumes are 1, 2, 5, 10, 20, 25, 50 and 100 mL. Volumetric pipettes are commonly used in analytical chemistry to make laboratory solutions from a base stock as well as to prepare solutions for titration. ASTM standard E969 defines the standard tolerance for volumetric transfer pipettes. The tolerance depends on the size: a 0.5-mL ...
The base-10 logarithm of a normalized number (i.e., a × 10 b with 1 ≤ a < 10 and b as an integer), is rounded such that its decimal part (called mantissa) has as many significant figures as the significant figures in the normalized number. log 10 (3.000 × 10 4) = log 10 (10 4) + log 10 (3.000) = 4.000000...
Probability bounds analysis gives the same answer as interval analysis does when only range information is available. It also gives the same answers as Monte Carlo simulation does when information is abundant enough to precisely specify input distributions and their dependencies. Thus, it is a generalization of both interval analysis and ...
That g-PDF is plotted with the histogram (black line) and the agreement with the data is very good. Also shown in Figure 2 is a g-PDF curve (red dashed line) for the biased values of T that were used in the previous discussion of bias. Thus the mean of the biased-T g-PDF is at 9.800 − 0.266 m/s 2 (see Table 1).
Download as PDF; Printable version; In other projects Wikidata item; ... Standard errors provide simple measures of uncertainty in a value and are often used because:
Any non-linear differentiable function, (,), of two variables, and , can be expanded as + +. If we take the variance on both sides and use the formula [11] for the variance of a linear combination of variables (+) = + + (,), then we obtain | | + | | +, where is the standard deviation of the function , is the standard deviation of , is the standard deviation of and = is the ...
Volumetric pipettes or bulb pipette allow the user to measure a volume of solution extremely precisely (precision of four significant figures). These pipettes have a large bulb with a long narrow portion above with a single graduation mark as it is calibrated for a single volume (like a volumetric flask ).
The Cramér–Rao bound [9] [10] states that the inverse of the Fisher information is a lower bound on the variance of any unbiased estimator of θ. Van Trees (1968) and Frieden (2004) provide the following method of deriving the Cramér–Rao bound , a result which describes use of the Fisher information.