Ads
related to: water and dust resistance testing for concrete design
Search results
Results from the WOW.Com Content Network
IS: 1199 – methods of sampling and analysis of concrete. IS: 516BXB JWJJS– methods of test for strength of concrete. IS: 13311 – ultrasonic testing of concrete structures. IS: 4925 – specifications for concrete batching plant. IS: 3025 – tests on water samples; IS: 4990 – specifications for plywood formwork for concrete.
Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration. ASTM Standard C1202-10. Standard Test Method for Surface Resistivity of Concrete's Ability to Resist Chloride Ion Penetration. Washington, D.C., USA: American Association of State Highway and Transportation Officials. 2011. AASHTO TP 95.
IP codes IP65 touchscreen display IP65 LED lamp. The IP code or ingress protection code indicates how well a device is protected against water and dust. It is defined by the International Electrotechnical Commission (IEC) under the international standard IEC 60529 [1] which classifies and provides a guideline to the degree of protection provided by mechanical casings and electrical enclosures ...
The ultimate strength of concrete is influenced by the water-cementitious ratio (w/cm), the design constituents, and the mixing, placement and curing methods employed.All things being equal, concrete with a lower water-cement (cementitious) ratio makes a stronger concrete than that with a higher ratio. [2]
The complete test requires 500 drum revolutions at a speed of 30-33 revolutions per minute. [6] Crushed sample is then separated from fine dust on a sieve, washed, dried and weighed. [6] The test reports loss of mass to abrasion and impact, expressed as a percentage of initial sample mass. [7]
A cover meter is an instrument to locate rebars and measure the exact concrete cover. Rebar detectors are less sophisticated devices that can only locate metallic objects below the surface. Due to the cost-effective design, the pulse-induction method is one of the most commonly used solutions. [1]
Micro-reinforced ultra-high-performance concrete is the next generation of UHPC. In addition to high compressive strength, durability and abrasion resistance of UHPC, micro-reinforced UHPC is characterized by extreme ductility, energy absorption and resistance to chemicals, water and temperature. [9]
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
Ads