  2. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    In the adjacent diagram, water pumped from the tower basin is the cooling water routed ... W = 0.1 to 0.3 percent of C for an induced draft cooling tower without ...

  3. File:Crossflow diagram.svg - Wikipedia

    en.wikipedia.org/wiki/File:Crossflow_diagram.svg

    This diagram is a retouched picture, ... Induced draft crossflow type cooling tower. {{fr}} schéma transversal d'une tour de refroidissement ...

  4. Draft (boiler) - Wikipedia

    en.wikipedia.org/wiki/Draft_(boiler)

    Normally it is done with the help of a forced draft fan. [2] Induced draft: When air or flue gases flow under the effect of a gradually decreasing pressure below atmospheric pressure. In this case, the system is said to operate under induced draft. The stacks (or chimneys) provide sufficient natural draft to meet the low draft loss needs.

  5. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    The draft (draught in British English) flow rate induced by the stack effect can be calculated with the equation presented below. [12] [13] The equation applies only to buildings where air is both inside and outside the buildings. For buildings with one or two floors, h is the height of the building and A is the flow area of the openings.

  6. Water cooling - Wikipedia

    en.wikipedia.org/wiki/Water_cooling

    Large mechanical induced-draft or forced-draft cooling towers in industrial plants continuously circulate cooling water through heat exchangers and other equipment where the water absorbs heat. That heat is then rejected to the atmosphere by the evaporation of some of the water in cooling towers where upflowing air contacts the downflowing water.

  7. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    The impacts include thermal pollution and killing large numbers of fish and other aquatic species at cooling water intakes. [17] [18] A Marley mechanical induced draft cooling tower. The heat absorbed by the circulating cooling water in the condenser tubes must also be removed to maintain the ability of the water to cool as it circulates.

  8. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    Vapor compression chillers may use any of a number of different types of compressors. Most common today are the hermetic scroll, semi-hermetic screw, or centrifugal compressors. The condensing side of the chiller can be either air or water cooled. Even when liquid cooled, the chiller is often cooled by an induced or forced draft cooling tower ...

  9. Spray pond - Wikipedia

    en.wikipedia.org/wiki/Spray_pond

    Specific spray pond surface areas tend to range between 1.2 and 1.7 m 2 per m 3 /h of water to be cooled. The width chosen for a drift channel around the active zone of the pond (containing the sprays) is dependent on a number of factors, including the prevailing wind strength, the average size of the spray droplets produced by the nozzles, and the presence of any nearby structures which may ...