Search results
Results from the WOW.Com Content Network
ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
[4] The model code, IECC, and the standard, ASHRAE 90.1, apply to commercial buildings. [5] [4] [6] The IECC references several ASHRAE Standards, in particular, ASHRAE 90.1 for commercial building construction. [22] Being a part of the ICC’s collection of model codes, the IECC is revised annually and published in full-form every three years.
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]
There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.
Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.
The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...
For example, R-22 has one carbon atom, one hydrogen atom (2−1 = 1), two fluorine atoms, and one chlorine atom (4−2−1 = 1), so it is chlorodifluoromethane, while R-134 has two carbon atoms (2−1 = 1), two hydrogen atoms (3−1 = 2), four fluorine atoms, and no chlorine atoms (6−2−4 = 0), so it is one of the tetrafluoroethanes. This ...
The committee’s goal was to have ASHRAE include minimum dehumidification efficiency requirements in ASHRAE Standard 90.1. [4] That standard is often used as the basis of building energy codes in the US and Canada, and also used worldwide as the baseline for voluntary energy programs such as LEED Certification (Leadership in Energy and ...