Results from the WOW.Com Content Network
Time response is measured by immersing the sensor in water moving at 1 m/s (3.3 ft/s) with a 63.2% step change. Size A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in diameter; sheath diameters for thermocouples can be less than 1.6 mm (0.063 in). Accuracy and stability requirements
When used in conjunction with a monitoring relay they provide overtemperature protection to prevent insulation damage. The equipment manufacturer selects a thermistor with a highly non-linear response curve where resistance increases dramatically at the maximum allowable winding temperature, causing the relay to operate.
The time of the temperature extreme, or GPS tracking, may be able to determine the location of the infraction to direct appropriate corrective action. Multiple replicate shipments of data loggers are also used to compare modes of shipment (routes, vendors) and to develop composite data to be used in package testing protocols.
Resistance temperature detector (RTD) Pyrometer; Langmuir probes (for electron temperature of a plasma) Infrared thermometer; Other thermometers; One must be careful when measuring temperature to ensure that the measuring instrument (thermometer, thermocouple, etc.) is really the same temperature as the material that is being measured.
An example response of system to sine wave forcing function. Time axis in units of the time constant τ. The response damps out to become a simple sine wave. Frequency response of system vs. frequency in units of the bandwidth f 3dB. The response is normalized to a zero frequency value of unity, and drops to 1/√2 at the bandwidth.
A thermocouple (the right most tube) inside the burner assembly of a water heater Thermocouple connection in gas appliances. The end ball (contact) on the left is insulated from the fitting by an insulating washer. The thermocouple line consists of copper wire, insulator and outer metal (usually copper) sheath which is also used as ground. [33]
In thermocouples the Seebeck effect is used to measure temperatures, and for accuracy it is desirable to use materials with a Seebeck coefficient that is stable over time. Physically, the magnitude and sign of the Seebeck coefficient can be approximately understood as being given by the entropy per unit charge carried by electrical currents in ...
In telecommunications, round-trip delay (RTD) or round-trip time (RTT) is the amount of time it takes for a signal to be sent plus the amount of time it takes for acknowledgement of that signal having been received. This time delay includes propagation times for the paths between the two communication endpoints. [1]