Search results
Results from the WOW.Com Content Network
Liquid oxygen has a clear cyan color and is strongly paramagnetic: it can be suspended between the poles of a powerful horseshoe magnet. [2] Liquid oxygen has a density of 1.141 kg/L (1.141 g/ml), slightly denser than liquid water, and is cryogenic with a freezing point of 54.36 K (−218.79 °C; −361.82 °F) and a boiling point of 90.19 K (−182.96 °C; −297.33 °F) at 1 bar (15 psi).
Medical use liquid oxygen airgas tanks are typically 2.4 MPa (350 psi). [citation needed] All equipment coming into contact with high pressure oxygen must be "oxygen clean" and "oxygen compatible", to reduce the risk of fire. [3] [4] "Oxygen clean" means the removal of any substance that could act as a source of ignition. "Oxygen compatible ...
Triangular diagrams are not commonplace. The easiest way to understand them is to briefly go through three basic steps in their construction. Consider the first triangular diagram below, which shows all possible mixtures of methane, oxygen and nitrogen. Air is a mixture of about 21 volume percent oxygen, and 79 volume percent inerts (nitrogen ...
A gas cylinder quad, also known as a gas cylinder bundle, is a group of high pressure cylinders mounted on a transport and storage frame. There are commonly 16 cylinders, each of about 50 litres capacity mounted upright in four rows of four, on a square base with a square plan frame with lifting points on top and may have fork-lift slots in the ...
Oxygen and MAPP gas compressed-gas cylinders with regulators Oxygen storage methods include high-pressure oxygen tanks , cryogenics and chemical compounds. For reasons of economy, oxygen is often transported in bulk as a liquid in specially insulated tankers, since one liter of liquefied oxygen is equivalent to 840 liters of gaseous oxygen at ...
Oxygen tanks containing pressures of up to 200 bar (3000 psi) are used for industrial processes including the manufacturing of steel and monel, welding and cutting, medical breathing gas, diving and as an emergency breathing gas in aircraft. A small steel tank of 16 litres water capacity with a working pressure of 139 bar (2015 psi), holds ...
Inert gas can also be used to purge the tank of the volatile atmosphere in preparation for gas freeing - replacing the atmosphere with breathable air - or vice versa. The flue gas system uses the boiler exhaust as its source, so it is important that the fuel/air ratio in the boiler burners is properly regulated to ensure that high-quality inert ...
In an oxygen system the presence of oxygen is implied, and in a sufficiently high partial pressure of oxygen, most materials can be considered fuel. Potential ignition sources are present in almost all oxygen systems, but fire hazards can be mitigated by controlling the risk factors associated with the oxygen, fuel, or heat, which can limit the ...