  2. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Current practice is to give separate services for single-phase and three-phase loads, e.g., 120 V split-phase (lighting etc.) and 240 V to 600 V three-phase (for large motors). However, many jurisdictions forbid more than one class for a premises' service, and the choice may come down to 120/240 V split-phase, 208 V single-phase or three-phase ...

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  4. Polyphase system - Wikipedia

    en.wikipedia.org/wiki/Polyphase_system

    One voltage cycle of a three-phase system. A polyphase system (the term coined by Silvanus Thompson) is a means of distributing alternating-current (AC) electrical power that utilizes more than one AC phase, which refers to the phase offset value (in degrees) between AC in multiple conducting wires; phases may also refer to the corresponding terminals and conductors, as in color codes.

  5. File:3 phase AC waveform.svg - Wikipedia

    en.wikipedia.org/wiki/File:3_phase_AC_waveform.svg

    This cycle will repeat 50 or 60 times per second, depending on the power system frequency. The colors of the lines represent the American color code for 120v three-phase. That is black=VL1 red=VL2 blue=VL3: Date: 30 December 2008: Source: File:3-fas-spänningar.svg: Author: User:J JMesserly modification of original svg by User:SiriusA: Other ...

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  7. Electrical code - Wikipedia

    en.wikipedia.org/wiki/Electrical_code

    120, 208, or 240 V. 277, or 480 V metallic brass 120, 208, or 240 V. 277, or 480 V metallic silver no insulation for isolated systems Flexible cable (e.g., extension, power, and lamp cords) 120 V metallic brass split-phase 240 V metallic silver CE Code (CSA C22.1) Canada [21] [h] for single-phase systems for three-phase systems no insulation

  8. IEC 60446 - Wikipedia

    en.wikipedia.org/wiki/IEC_60446

    The international standard IEC 60446 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors was a standard published by the International Electrotechnical Commission (IEC) that defined basic safety principles for identifying electrical conductors by colours or numerals, for example in ...

  9. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase. Since these two modes do not need three phases there is also a dark yellow-orange four-pin connector available designed for a single-phase 110–120 or 220–240 volt load.