enow.com Web Search

  1. Ad

    related to: current magnetosphere temperature limit test for water supply valve

Search results

  1. Results from the WOW.Com Content Network
  2. Steam and water analysis system - Wikipedia

    en.wikipedia.org/wiki/Steam_and_water_analysis...

    These valves close and block samples to analyzer in case of cooling water failures. These valves must be with: (1) High pressure rating and designed inline with ASME standards to assure safety of operator and instruments downstream. (2) This valves must be with MANUAL RESET design as recommended in ASME PTC 19.11-2008 standards.

  3. Thermostatic mixing valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_mixing_valve

    A thermostatic mixing valve (TMV) is a valve that blends hot water with cold water to ensure constant, safe shower and bath outlet temperatures to prevent scalding. The storage of water at high temperature removes one possible breeding ground for Legionella; the use of a thermostat, rather than a static mixing valve, provides increased safety ...

  4. Solenoid valve - Wikipedia

    en.wikipedia.org/wiki/Solenoid_valve

    A solenoid valve is an electromechanically operated valve. Solenoid valves differ in the characteristics of the electric current they use, the strength of the magnetic field they generate, the mechanism they use to regulate the fluid, and the type and characteristics of fluid they control. The mechanism varies from linear action, plunger-type ...

  5. Thermocouple - Wikipedia

    en.wikipedia.org/wiki/Thermocouple

    Thermocouple. A thermocouple, also known as a "thermoelectrical thermometer", is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction. A thermocouple produces a temperature-dependent voltage as a result of the Seebeck effect, and this voltage can be interpreted to measure temperature.

  6. Hydrostatic test - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_test

    A hydrostatic test is a way in which pressure vessels such as pipelines, plumbing, gas cylinders, boilers and fuel tanks can be tested for strength and leaks. The test involves filling the vessel or pipe system with a liquid, usually water, which may be dyed to aid in visual leak detection, and pressurization of the vessel to the specified test ...

  7. Breathing performance of regulators - Wikipedia

    en.wikipedia.org/wiki/Breathing_performance_of...

    The US Navy procedure has been to test regulators primarily at a depth of 190 fsw (58 msw) in water 28 to 29 °F (−2 to −2 °C) at a very high breathing rate of 62.5 lpm for a minimum of 30 minutes, with inlet pressure to the first stage of 1,500 pounds per square inch (100 bar), which results in an average second stage inlet temperature of ...

  8. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    Pressure regulator for domestic water supply. Outlet pressure is set with the blue handwheel and shown on the vertical scale. A water pressure regulating valve limits inflow by dynamically changing the valve opening so that when less pressure is on the outside, the valve opens up fully, and too much pressure on the outside causes the valve to shut.

  9. Thermodynamic pump testing - Wikipedia

    en.wikipedia.org/wiki/Thermodynamic_pump_testing

    The thermodynamic method is used for performance testing of pumps, flow meter calibration, system curve tests, and other applications. It is capable of achieving results with uncertainties of less than 1% in pump efficiency and less than 1.5% in flow [3] while being able to test piping configurations where other conventional pump testing ...

  1. Ad

    related to: current magnetosphere temperature limit test for water supply valve