enow.com Web Search

  1. Ads

    related to: rtd sensor vs thermocouple code box 2

Search results

  1. Results from the WOW.Com Content Network
  2. Resistance thermometer - Wikipedia

    en.wikipedia.org/wiki/Resistance_thermometer

    A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in diameter; sheath diameters for thermocouples can be less than 1.6 mm (0.063 in). Accuracy and stability requirements If a tolerance of 2 °C is acceptable and the highest level of repeatability is not required, a thermocouple will serve.

  3. List of temperature sensors - Wikipedia

    en.wikipedia.org/wiki/List_of_temperature_sensors

    The integrated circuit sensor may come in a variety of interfaces — analogue or digital; for digital, these could be Serial Peripheral Interface, SMBus/I 2 C or 1-Wire.. In OpenBSD, many of the I 2 C temperature sensors from the below list have been supported and are accessible through the generalised hardware sensors framework [3] since OpenBSD 3.9 (2006), [4] [5]: §6.1 which has also ...

  4. Callendar–Van Dusen equation - Wikipedia

    en.wikipedia.org/wiki/Callendar–Van_Dusen_equation

    The Callendar–Van Dusen equation is an equation that describes the relationship between resistance (R) and temperature (T) of platinum resistance thermometers (RTD). As commonly used for commercial applications of RTD thermometers, the relationship between resistance and temperature is given by the following equations.

  5. Signal conditioning - Wikipedia

    en.wikipedia.org/wiki/Signal_conditioning

    Sensor inputs can be accelerometer, thermocouple, thermistor, resistance thermometer, strain gauge or bridge, and LVDT or RVDT. Specialized inputs include encoder, counter or tachometer, timer or clock, relay or switch, and other specialized inputs. Outputs for signal conditioning equipment can be voltage, current, frequency, timer or counter ...

  6. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    This type of heat detector can operate at a lower temperature fire condition than would be possible if the threshold were fixed. It has two heat-sensitive thermocouples or thermistors. One thermocouple monitors heat transferred by convection or radiation, while the other responds to ambient temperature.

  7. Thermopile laser sensor - Wikipedia

    en.wikipedia.org/wiki/Thermopile_laser_sensor

    Figure 2: [8] Working principle of a thermal laser sensor (Adapted from figure 3 with permission) As shown in Fig 2, a thermopile laser sensor consists of several thermocouples connected in series with one junction type (hot junction at temperature T 1) being exposed to an absorption area and the other junction type (cold junction at temperature T 2) being exposed to a heat sink.

  8. Thermopile - Wikipedia

    en.wikipedia.org/wiki/Thermopile

    The two top thermocouple junctions are at temperature T 1 while the two bottom thermocouple junctions are at temperature T 2. The output voltage from the thermopile, ΔV , is directly proportional to the temperature differential, ΔT or T 1 - T 2 , across the thermal resistance layer and number of thermocouple junction pairs.

  9. Test probe - Wikipedia

    en.wikipedia.org/wiki/Test_probe

    A thermocouple probe. Temperature probes are used to make contact measurements of surface temperatures. They employ a temperature sensor such as a thermistor, thermocouple, or RTD, to produce a voltage that varies with temperature. In the case of thermistor and RTD probes, the sensor must be electrically stimulated to produce a voltage, whereas ...