Ad
related to: pipe flow pressure drop calculator for air
Search results
Results from the WOW.Com Content Network
The flow rate can be converted to a mean flow velocity V by dividing by the wetted area of the flow (which equals the cross-sectional area of the pipe if the pipe is full of fluid). Pressure has dimensions of energy per unit volume, therefore the pressure drop between two points must be proportional to the dynamic pressure q.
In non ideal fluid dynamics, the Hagen–Poiseuille equation, also known as the Hagen–Poiseuille law, Poiseuille law or Poiseuille equation, is a physical law that gives the pressure drop in an incompressible and Newtonian fluid in laminar flow flowing through a long cylindrical pipe of constant cross section.
For example, halving a pipe's diameter would increase the pressure drop by a factor of = (e.g. from 2 psi to 64 psi), assuming no change in flow. Pressure drop in piping is directly proportional to the length of the piping—for example, a pipe with twice the length will have twice the pressure drop, given the same flow rate. [8]
For air with a heat capacity ratio =, then =; other gases have in the range 1.09 (e.g. butane) to 1.67 (monatomic gases), so the critical pressure ratio varies in the range < / <, which means that, depending on the gas, choked flow usually occurs when the downstream static pressure drops to below 0.487 to 0.587 times the absolute pressure in ...
A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.
In engineering, the Moody chart or Moody diagram (also Stanton diagram) is a graph in non-dimensional form that relates the Darcy–Weisbach friction factor f D, Reynolds number Re, and surface roughness for fully developed flow in a circular pipe. It can be used to predict pressure drop or flow rate down such a pipe.
A graphical depiction of the relationship between Δp / L, the pressure loss per unit length of pipe, versus flow volume Q, for a range of choices for pipe diameter D, for air at standard temperature and pressure. Units are SI. Lines of constant Re √ f D are also shown. [17]
[4] [5] [6] A generalized model of the flow distribution in channel networks of planar fuel cells. [6] Similar to Ohm's law, the pressure drop is assumed to be proportional to the flow rates. The relationship of pressure drop, flow rate and flow resistance is described as Q 2 = ∆P/R. f = 64/Re for laminar flow where Re is the Reynolds number.
Ad
related to: pipe flow pressure drop calculator for air