enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. High-resolution computed tomography - Wikipedia

    en.wikipedia.org/wiki/High-resolution_computed...

    Low-dose high-resolution (1.25 mm) chest CT. HRCT is performed using a conventional CT scanner. However, imaging parameters are chosen so as to maximize spatial resolution: [1] a narrow slice width is used (usually 1–2 mm), a high spatial resolution image reconstruction algorithm is used, field of view is minimized, so as to minimize the size of each pixel, and other scan factors (e.g. focal ...

  3. CT scan - Wikipedia

    en.wikipedia.org/wiki/CT_scan

    Two helical CT scanning parameters, tube current and pitch, can be adjusted easily and have a profound effect on radiation. CT scanning is more accurate than two-dimensional radiographs in evaluating anterior interbody fusion, although they may still over-read the extent of fusion. [147]

  4. Computed tomography of the chest - Wikipedia

    en.wikipedia.org/wiki/Computed_tomography_of_the...

    Modern detail-oriented scans such as high-resolution computed tomography (HRCT) is the gold standard in respiratory medicine and thoracic surgery for investigating disorders of the lung parenchyma . Contrasted CT scans of the chest are usually used to confirm diagnosis of for lung cancer and abscesses , as well as to assess lymph node status at ...

  5. Operation of computed tomography - Wikipedia

    en.wikipedia.org/wiki/Operation_of_computed...

    In conventional CT machines, an X-ray tube and detector are physically rotated behind a circular shroud (see the image above right). An alternative, short lived design, known as electron beam tomography (EBT), used electromagnetic deflection of an electron beam within a very large conical X-ray tube and a stationary array of detectors to achieve very high temporal resolution, for imaging of ...

  6. Maximum intensity projection - Wikipedia

    en.wikipedia.org/wiki/Maximum_intensity_projection

    SPECT visualized by a MIP of a mouse Types of presentations of CT scans: - Average intensity projection - Maximum intensity projection - Thin slice (median plane)- Volume rendering by high and low threshold for radiodensity.

  7. Hounsfield scale - Wikipedia

    en.wikipedia.org/wiki/Hounsfield_scale

    The Hounsfield unit (HU) scale is a linear transformation of the original linear attenuation coefficient measurement into one in which the radiodensity of distilled water at standard pressure and temperature is defined as 0 Hounsfield units (HU), while the radiodensity of air at STP is defined as −1000 HU.

  8. Electron beam computed tomography - Wikipedia

    en.wikipedia.org/wiki/Electron_beam_computed...

    Electron beam CT scanners are considered a fifth generation CT scanner, with first generation being the pencil beam with translation and rotation, second generation being a fan beam with similar motion to its predecessor, third generation having both rotating fan beam and detectors and fourth generation being a fan beam with a rotating movement but fixed detector.

  9. Medical imaging - Wikipedia

    en.wikipedia.org/wiki/Medical_imaging

    Volume rendering techniques have been developed to enable CT, MRI and ultrasound scanning software to produce 3D images for the physician. [24] Traditionally CT and MRI scans produced 2D static output on film. To produce 3D images, many scans are made and then combined by computers to produce a 3D model, which can then be manipulated by the ...