  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The cooling load temperature difference (CLTD) calculation method, also called the cooling load factor (CLF) or solar cooling load factor (SCL) method, is a method of estimating the cooling load or heating load of a building. It was introduced in the 1979 ASHRAE handbook.

  3. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The COP of absorption chillers can be improved by adding a second or third stage. Double and triple effect chillers are significantly more efficient than single effect chillers, and can surpass a COP of 1. They require higher pressure and higher temperature steam, but this is still a relatively small 10 pounds of steam per hour per ton of cooling.

  4. European seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/European_seasonal_energy...

    In the United Kingdom, a Seasonal Energy Efficiency ratio (SEER) for refrigeration and air conditioning products, similar to the ESEER but with different load profile weighting factors, is used for part of the Building Regulations Part L calculations within the Simplified Building Energy Model (SBEM) software, and are used in the production of Energy Performance Certificates (EPC) for new ...

  5. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    In the United States, the efficiency of air conditioners is often rated by the seasonal energy efficiency ratio (SEER) which is defined by the Air Conditioning, Heating, and Refrigeration Institute, a trade association, in its 2008 standard AHRI 210/240, Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment. [1]

  6. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...

  7. Logarithmic mean temperature difference - Wikipedia

    en.wikipedia.org/wiki/Logarithmic_mean...

    When the two temperature differences are equal, this formula does not directly resolve, so the LMTD is conventionally taken to equal its limit value, which is in this case trivially equal to the two differences. With this definition, the LMTD can be used to find the exchanged heat in a heat exchanger:

  8. Cascade refrigeration - Wikipedia

    en.wikipedia.org/wiki/Cascade_refrigeration

    An example two-stage process is shown at right. (Bottom on mobile) The cascade cycle is often employed for devices such as ULT freezers. [1] In a cascade refrigeration system, two or more vapor-compression cycles with different refrigerants are used.

  9. Exergy efficiency - Wikipedia

    en.wikipedia.org/wiki/Exergy_efficiency

    As an example the combustion process inside a power stations gas turbine is highly irreversible and approximately 25% of the exergy input will be destroyed here. For fossil fuels the free enthalpy of reaction is usually only slightly less than the enthalpy of reaction so from equations ( 3 ) and ( 4 ) we can see that the energy efficiency will ...