Search results

  1. Results from the WOW.Com Content Network
  2. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    A shunt-trip unit appears similar to a normal breaker and the moving actuators are ganged to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or DC. These are often used to cut ...

  3. Disconnector - Wikipedia

    en.wikipedia.org/wiki/Disconnector

    Unlike load switches and circuit breakers, disconnectors lack a mechanism for suppression of electric arcs which occur when conductors carrying high currents are mechanically interrupted. Thus, they are off-load devices, with very low breaking capacity , intended to be opened only after the current has been interrupted by some other control device.

  4. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    A shunt is a device that is designed to provide a low-resistance path for an electrical current in a circuit. It is typically used to divert current away from a system or component in order to prevent overcurrent .

  5. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Switchgear is a combination of electrical disconnect switches, fuses or circuit breakers used to control, protect and isolate electrical equipment. Switches are safe to open under normal load current (some switches are not safe to operate under normal or abnormal conditions), while protective devices are safe to open under fault current.

  6. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    Sometimes as a precaution against out-of-step connection of a machine to a system, a "synchro check" relay is installed that prevents closing the generator circuit breaker unless the machine is within a few electrical degrees of being in-phase with the system. Synchro check relays are also applied in places where several sources of supply may ...

  7. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    After the 1970s, vacuum switches began to replace the minimal-oil switches in medium-voltage switchgear. In the early 1980s, SF6 switches and breakers were also gradually replaced by vacuum technology in medium-voltage application. As of 2018, a vacuum circuit-breaker had reached 145 kV with a short-circuit rating of 200 kA. [4]

  8. Fault current limiter - Wikipedia

    en.wikipedia.org/wiki/Fault_current_limiter

    Electric power distribution systems include circuit breakers to disconnect power in case of a fault, but to maximize reliability, they wish to disconnect the smallest possible portion of the network. This means that even the smallest circuit breakers, as well as all wiring to them, must be able to disconnect large fault currents. [citation needed]

  9. Transfer switch - Wikipedia

    en.wikipedia.org/wiki/Transfer_switch

    Simplified single line diagram of a single-phase transfer switch to select either 'city' (utility) power or local generator power 3-phase Intelligent transfer switch. A transfer switch is an electrical switch that switches a load between two sources.