A P wave with increased amplitude can indicate hypokalemia. [3] It can also indicate right atrial enlargement. [4] A P wave with decreased amplitude can indicate hyperkalemia. [5] P-wave changes in left and right atrial hypertrophy. Bifid P waves (known as P mitrale) indicate left-atrial abnormality - e.g. dilatation [6] or hypertrophy. [1]
The term normal sinus rhythm (NSR) is sometimes used to denote a specific type of sinus rhythm where all other measurements on the ECG also fall within designated normal limits, giving rise to the characteristic appearance of the ECG when the electrical conduction system of the heart is functioning normally; however, other sinus rhythms can be ...
The whole ECG course on 1 A4 paper from ECGpedia, a wiki encyclopedia for a course on interpretation of ECG; Wave Maven – a large database of practice ECG questions provided by Beth Israel Deaconess Medical Center; PysioBank – a free scientific database with physiologic signals (here ecg) EKG Academy – free EKG lectures, drills and quizzes
A wandering atrial pacemaker can be either normal or irregular in rate, much like a sinus arrhythmia the rate is normally between 60 - 100 bpm when it is normal and less than 60 when it is slow, the distinguishing feature of this rhythm is a p wave that varies in size, shape, and direction, the PR interval can either be normal or irregular ...
Not every QRS complex contains a Q wave, an R wave, and an S wave. By convention, any combination of these waves can be referred to as a QRS complex. However, correct interpretation of difficult ECGs requires exact labeling of the various waves. Some authors use lowercase and capital letters, depending on the relative size of each wave.
On an ECG, the QRS complex will be abnormally shaped when looking at ventricular ectopic activity, often it occurs earlier with an absent P wave. It can be perceived as a skipped beat on both the ECG and through normal pulse-taking. [12] During atrial ectopic activity where the P wave is normally rounded can be inverted or peaked.
The hexaxial reference system can be used to visualise the directions in which the depolarisation wave may travel. On a hexaxial diagram (see figure 1): If the electrical axis falls between the values of -30° and +90° this is considered normal. If the electrical axis is between -30° and -90° this is considered left axis deviation.
To make the diagnosis, there must be at least 3 different P-wave morphologies in a single ECG lead due to the shifting of the pacemaker in the atria. [1] This is different from normal sinus rhythm where one will see the same P-wave morphology through the same lead because each beat is started from the SA node. The P-wave is normally upright or ...